Packaging
elements
polystyrene foam, staples ...) must not be left
within reach of children.
6.2.
Installation
Commissioning and installation procedures
are to be performer by qualified personnel.
!
Installation and assembly operations must
be carried out in accordance with current safety
regulations.
!
The equipment used for installation and
assembly operations must comply with current
safety standards.
All the installation phases must be considered,
from the moment of creation of the general plan.
The installation area must be equipped with all
power supply and production residue drainage
connections and must be suitably lit and respect
current laws regarding hygiene and sanitary
requirements.
The
performance
guaranteed with a room temperature of 32°C. A
higher
temperature
can
performance and, in more serious cases, cause
the appliance's protections to start up.
Therefore, consider the most critical room
conditions that can be reached in that position
before making a choice.
Level the appliance by acting on the individual
feet.
!
It is essential that the equipment is level;
otherwise, the operation of the machine may be
impaired
Install the equipment so that the workstation is
positioned in front of the control panel.
Do not push or drug the device during
installation to avoid tipping or damages to parts of
it.
(nylon
bags,
of
the
appliance
is
compromise
its
Remove the protective PVC film from the internal
and external walls, avoiding the use of metal
tools.
Packaging must be disposed of in accordance
with the regulations in force in the country where
the equipment is used.
!
This appliance can only be installed and
operate
in
rooms,
ventilated, in order to guarantee correct operation.
Connect and leave for a certain period of
time
(at
least
2
functioning. During transport, it is probable that
the compressor lubricant oil has entered the
refrigerant circuit blocking the capillary: as a
consequence the appliance will function for a
certain period of time without producing cold until
the oil has returned to the
The equipment requires the following
minimum functional spaces:
•
at least 50 cm from the top
•
30 mm from the back panel
To avoid condensation on the walls of the
equipment, it is advisable to keep at least 50 mm
between one unit and the next.
The defrosting water and the water that
forms
at
the
bottom
compartment during operation or during periodical
internal cleaning must be drained through a
prearranged hose with a minimum diameter 3/4"
connected to the hose at the bottom of the chiller.
A drain trap should also be guaranteed. The drain
must comply with Standards in force.
!
The size of the compartment that houses the
equipment must be such as to avoid excessive
concentrations of gas in the event of a leak from
the refrigeration circuit and in any case, the
compartment must have a free area NEVER
smaller than 4 times the space occupied by the
equipment. Adequate space must be provided to
ensure effective escape routes at all times. The
above-mentioned compartment must be well
ventilated.
11
ENGLISH
which
are
permanently
hours)
before
checking
compressor.
of
the
refrigerating
GB