Safety Devices
During the running of appliance, some control
devices may activate and govern the correct
running of the machine. In other cases, they may
deactivate parts or the whole machine, to put the
appliance in safe conditions. Main controls are
described below.
Micro Door Switch
In case the door is opened,
the magnetic switch placed on the control board
opens and, during blast-chilling or shock-freezing,
evaporator fans go off ; if the opening persist for a
longer period than the one established on
parameter i2, it will appear on the display the
alarm "id" together with a sound signal (until the
door is closed).
That condition may also be determined when the
door is not perfectly aligned to or near the control
board.
Protective Fuses
Some protection fuses in the general power
supply line are activated in case of overload.
Room Temperature
32°C
EN ISO 23953
Relative Humidity
30°C-
Condenser Temperature Alarm
conditions or functional failures, which cause the
condenser to exceed the maximum temperature
value established on parameter C6, the alarm
"COH" will appear on the display, the condenser
fan will start.
If the temperature detected by
the condenser probe is higher than the in
parameter C7 established value, the display will
show the alarm "CSd"; the running cycle will be
stopped. The machine can be run when an
acceptable temperature value is reset.
Electrical Power Supply Failure
In the event of a power failure
during a working cycle for a period exceeding the
value established on parameter A10, once
restored the electricity the display will show the
alarm "PF".