Descargar Imprimir esta página

Eurofred 4T Manual De Instalación, Uso Y Mantenimiento página 48

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 129
7.2.
Description of Controls
GB
Below a brief description of the functions
performed by the control panel buttons.
Blast Chilling Key
Pressing the key with machine still, allows the
selection of a temperature blast chilling cycle
(+90°C+3°C). Led
A second pressure of the key allows to select a
timed blast chilling cycle: led
turns on.
Shock Freezing Key
Pressing the key with machine still, allows the
selection of a temperature shock freezing cycle
(+90°C-18°C). ). Led
A second pressure of the key allows to select a
timed shock freezing cycle: led
turns on.
Time setting Keys
If timed chilling or freezing mode has been
selected, these keys make it possible to set the
number of minutes the cycle will last.
If temperature chilling or freezing mode has been
selected, these keys make it possible to set the
end chilling or freezing temperature.
Start Key
Once chosen the needed cycle, it can be started
by pressing this key,
If pressed during functioning, the machine will
stop; the previously chosen cycle will persist and
can be run immediately.
By pressing this button for at least 5 seconds, the
machine passes to the stand-by mode. Repeat
the procedure to reactivate the board.
ENGLISH
and
are on.
is off and led
and
turn on.
is off and led
DEFROST Key
When the machine is off a manual defrosting
cycle can be started.
If the key is pressed again, the defrosting in
progress can be stopped.
Display: symbols description
blinking: a blast chilling cycle has been
selected.
on: running blast chilling cycle.
blinking: a shock freezing cycle has been
selected.
On: running shock freezing cycle.
blinking: an intensive blast chilling or
shock freezing cycle has been selected.
on: an intensive blast chilling or shock
freezing cycle is running.
: over cooling function on
: preserving cycle on
: temperature cycle on
: timed cycle on
: defrosting cycle on
: new HACCP alarms stored
: stand-by mode
14