12.2
Message guide
Message
Possible Cause
Communication Fault Cable has
disconnected from
controller or PI box
Count Fault
Operator backed out
a fastener
Program Fault
Operator performed a
double hit or fastened
more fasteners than
was expected
Tool Update Failed
Tool INI file is corrupt Download a new file
Loss of
communication
between tool and
controller
PLC Message
The PLC is providing
the message
Invalid PLC File
Bad command or
syntax used in the
PLC.json file
Identifying Spindle
Trailing spindle is
wanting to connect to
lead controller
Operator pressed the
Identify button under
ANALYZE
Tool Disabled
An unprogrammed
Task has been
selected
A non-valid Job/ Task
has been selected
Probable Solution
Major Considera-
tion That Led to
Solution
Reconnect cable
Visual inspection
Re-fasten loosened
Actual bolt count on
fastener
display is less than
required
Reset Job or loosen
Actual bolt count on
a secured fastener to
display is more than
return to the proper
required
bolt count
Tool Update Failed
and try to load it
error message
again
appears.
See Tool
Tool
Communications! In
Communications!
section "9.2.1 Fault
fault on display
Guide" on page 184
None
PLC Message is
displayed on
controller
Read the entire file
Invalid PLC File
and fix the syntax
appears on display
issue
Choose a number
Red, Greed, Yellow
and add the spindle
Status lights are
blinking in sequence
on trailing controller
and tool with 'Add
Spindle' dialog box
on display of lead
controller
Press OK
Display on lead
controller is on
ANALYZE screen
Select a different
Tool Disabled:
Task
Undefined Task
message on display
when the operator
pressed the tool's
start trigger
Select a different
Tool Disabled:
Job/Task
Invalid Job/Task
message on display
when the operator
pressed the tool's
start trigger
SC Series Controllers
Troubleshooting
To Clear/Reset from
Message Condition
Reconnect cable
Re-fasten loosened
fastener
Reset Job or loosen
a fastened fastener
Download a new file
and try to load it
again
See Tool
Communications! In
section "9.2.1 Fault
Guide" on page 184
Press OK
Press OK.
Delete the PLC file.
Read the entire file
and fix the syntax
issue.
Press OK.
Choose a number
and add the spindle
Press OK
Program the selected
Task or select
another Task that is
already programmed
Select a different
Job/Task from 1 to
99