Descargar Imprimir esta página

Stanley SC Serie Manual De Instrucciones página 73

Publicidad

Outputs
Description
Spindle: Type the spindle number from which the signal comes.
MULTI-FUNCTION
Asserts when the tool's Multi-function Button is pressed. Resets when the Multi-function
BUTTON
Button is released.
Size: 1 bit
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Output Type: Normal, Timed, Flash
Minimum ON Time, Time, Period
Spindle: Type the spindle number from which the signal comes.
NOT USED
The output is not used. This is essentially a placeholder.
For fieldbus, the length of this input function may be set to any size that meets the need.
*PARAMETER
This output is the value of the selected Parameter. It changes when the parameter
changes.
Size: Can be any size from 0 to 32 bytes depending on Data Type
Data Type: Float, Int8, Int16, Int32, Fixed Point, String
Parameter: Strategy, Torque Target, High Torque, Low Torque, Angle Target, High Angle,
Low Angle, Snug Torque, Speed, Step Name, Torque Cal, Tool Serial Number, Torque
Bailout, Angle Bailout, Downshift Torque, Downshift Speed, Tool Model Number, Task
Name, Job Name, Task Bolt Count.
Step: Audit, Audit-1, Audit-2
Spindle: Type the spindle number from which the signal comes.
*PART ID
This value is equal to and changes as the PART ID input changes.
Size: Can be any size from 0 to 32 bytes depending on Data Type
Data Type: Float, Int8, Int16, Int32, Fixed Point, String
Spindle: Type the spindle number from which the signal comes.
PM
Asserts when the Preventive Maintenance Count in the tool's memory has exceeded the
Preventive Maintenance Threshold. Resets when the Preventive Maintenance Count is
reset to zero.
Size: 1 bit
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Output Type: Normal, Timed, Flash
Minimum ON Time, Time, Period
Spindle: Type the spindle number from which the signal comes.
READY
Asserts when there is no fault on the controller and the tool is ready to run. This output
resets when the tool is disabled. The blue light on the controller and tool will illuminate
when this output is on.
Size: 1 bit
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Output Type: Normal, Timed, Flash
Minimum ON Time, Time, Period
Spindle: Type the spindle number from which the signal comes.
RED LIGHT
Mimics the Red status lights on the tool.
Size: 1 bit
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Output Type: Normal, Timed, Flash
Minimum ON Time, Time, Period
Spindle: Type the spindle number from which the cycle status comes.
SC Series Controllers
Configuration
73 / 1032

Publicidad

loading

Este manual también es adecuado para:

Scn