Descargar Imprimir esta página

Stanley SC Serie Manual De Instrucciones página 71

Publicidad

Outputs
Description
Size: 1 bit
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Output Type: Normal, Timed, Flash
Minimum ON Time, Time, Period
Spindle: Type the spindle number from which the cycle status comes.
CYCLE STOPPED Asserts when the tool shuts off due to a loss of Start signal or the operator released the
trigger before the target was achieved. Resets when the tool is commanded to run again.
Can also be reset with the RESET RESULTS STATUS input.
Size: 1 bit
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Output Type: Normal, Timed, Flash
Minimum ON Time, Time, Period
Spindle: Type the spindle number from which the cycle status comes.
DISASSEMBLY
Asserts when the tool is running in Reverse and the achieved torque value exceeds the
Threshold Torque value through some rotation. Resets when the tool is stopped.
DETECTED
Size: 1 bit
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Output Type: Normal, Timed, Flash
Minimum ON Time, Time, Period
Spindle: Type the spindle number from which the disassembly status comes.
*FAULT CODE
This output is the number value of the fault code present in the controller. It asserts when a
fault is active and resets when the fault clears. The values are as follows:
1 – Overcurrent Fault! 2 – Logic Voltage Fault!
3 – Position Feedback Fault! 4 – Transducer Span Fault!
5 – Temperature Fault! 6 – Unrecognized Tool!
7 – Tool Communications! 8 – Transducer Current Fault!
9 – Transducer Zero Fault! 10 – Unused
11 – Unused 12 – Unused
13 – Unsupported Tool! 14 – GFI Fault!
15 – Servo Connection Fault!
Size: Can be any size from 0 to 32 bytes depending on Data Type
Data Type: Float, Int8, Int16, Int32, Fixed Point, String
Spindle: Type the spindle number from which the fault code comes.
FAULTED
Asserts when there is a fault on the controller. Resets when the fault clears.
Size: 1 bit
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Output Type: Normal, Timed, Flash
Minimum ON Time, Time, Period
Spindle: Type the spindle number from which the fault comes.
GREEN LIGHT
Mimics the Green status lights on the tool.
Size: 1 bit
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Output Type: Normal, Timed, Flash
Minimum ON Time, Time, Period
Spindle: Type the spindle number from which the cycle status comes.
SC Series Controllers
Configuration
71 / 1032

Publicidad

loading

Este manual también es adecuado para:

Scn