Descargar Imprimir esta página

Stanley SC Serie Manual De Instrucciones página 88

Publicidad

SC Series Controllers
Configuration
Lights (1, 2)
● Defines whether the lights indicate a Job or Task.
Headlight Timer
Sets the time the tool's headlights remain on, in seconds, after the trigger is pressed.
Enable Tool Light Timer
If enabled the timer and the tool's Red, Green and Yellow status lights will illuminate for the period of time
specified after a fastening cycle and then extinguish.
If disabled the time is disabled and the tool's Red, Green and Yellow status lights will remain illuminated after a
fastening cycle until the tool is started again. They will only extinguish while the tool is running.
● Tool Light Timer
The time in seconds the Red, Green and Yellow status lights will remain on after a fastening cycle.
Save the changes.
8.1.7.4
Tones
Under Setup Card header -> Select Other Card -> Tones
The alarm in the tool handle can emit different tones based on the status of the fastening cycle. Choose an
Accept Tone for an OK Fastening cycle and a Reject Tone for a NOK Fastening cycle.
Save the changes.
8.1.7.5
Tool
Under Setup Card Header ->Select Other Card -> Tool
Values modified under this tab are saved to the tool not the controller. Users must have TOOL or
ADMINISTRATOR access level to modify these values. The "Update tool" exit window appears anytime
changes are made in this tab.
PM Limit
When the PM Counter in the tool exceeds this threshold, the preventive maintenance indicator on the front
panel illuminates indicating it is time to perform maintenance on the attached tool.
Temperature Limit
Identifies the threshold, in degrees Celsius, for tool shut off. This is caused by excessive duty cycle on the tool.
Torsion Factor
See Appendix A – Torsion Compensation for an explanation of this parameter and how to determine a correct
value. Otherwise, use the default (zero).
88 / 1032

Publicidad

loading

Este manual también es adecuado para:

Scn