Descargar Imprimir esta página

Stanley SC Serie Manual De Instrucciones página 38

Publicidad

SC Series Controllers
Configuration
Name
Name the Job to define the operation performed (15-character maximum). Name field is visible in many external
applications.
Barcode ID
This is a mask that when equal to an incoming PART ID (barcode scan) this Job is selected as the active Job.
The PART ID can come from the USB port, serial port, a network protocol, a fieldbus input, the internal PLC or
the keypad itself. Use periods (.) to mask the negligible portions of the PART ID; use the exact characters in
their exact PART ID positions to select the Job.
Example: If a PART ID is 123ABC and if the 3A determines when this Job is to run (the third and fourth
positions), then enter "..3A.." as the parameter value. Notice that the periods (.) match the length of the
expected PART ID.
Increment Count on NOK
Setting this parameter to Yes will allow the selected Job's bolt count to increment on both OK and NOK
fastening cycles. If set to No the Job's bolt count will increment only on OK fastening cycles.
Auto Sequence Tasks
When set to Yes, the application automatically increments or decrements from the selected task to the
completion of the job after the fastener count in each Task is complete.
Auto Reset Job
When enabled, the job resets between batches instead of waiting for an external job reset.
Enable Error Proofing
Enables the error-proofing features with additional parameter options settings. Additionally, disables tool when
batch count is met.
1. Disable Disassembly:
This section identifies whether the tool removes the Disassembly (Reverse) function on one of the following
events.
● On Cycle OK
If enabled, does not allow the use of Disassembly mode after each OK fastening cycle.
● On Job Complete
If enabled, does not allow the use of Disassembly mode after the active Job is complete (accumulated
count equals target count).
● On All Fasteners Removed
If enabled, does not allow the use of Disassembly mode after all fasteners have been removed i.e. accu-
mulated count is back to zero.
2. Disable Assembly:
38 / 1032

Publicidad

loading

Este manual también es adecuado para:

Scn