Descargar Imprimir esta página

Stanley SC Serie Manual De Instrucciones página 57

Publicidad

NPL Settings
Use these setting when implementing the NPL protocol communications at Fiat facilities.
● Batch Mode
This is for batch processing and printer support.
● DISABLE: Batch process is disabled.
● No Mes: Perform the batch process and printer output without the Mes command
● Mes: Perform the batch process and printer output with the Mes command.
● Operation Mode
● MANUAL: Keep Alive messages are not sent.
● AUTO: Sends keep alive messages as necessary.
● Manual Messaging
● Enable: Send data to the Mes while in Manual Mode.
● Disable: Do not send data to the Mes while in Manual Mode
● Buffer Size
The size in characters to set aside to receive network messages. Maximum size is 4096 characters (bytes).
● Transfer Mode
For Smart NPL only.
● Mode 1: NOKs are sent when they happen (TR) and in final message when the Job is complete (ER).
● Mode 2: NOKs are sent when they happen (TR) and sent in the final message only when the Job failed.
OKs are send as ER when Job is complete and passes.
● Mode 3: All results are sent as they happen (TR). Final fastening cycle in Job is sent as ER.
Rundown Data
Specify the PART ID as Vin or Avi.
● Vin
Vehicle identification number
● Avi
Automated vehicle identifier
Buffer While Offline
Enable will allow the controller to buffer the fastening cycle data while the controller is offline (disconnected from
the network). When disable the controller will not buffer data for network retrieval.
Version
This is the installed version of the PFCS protocol. Check with the Chrysler's Systems group to determine if this
has been approved for use in the facility.
Save the changes.
8.1.2.6
TOOLSNET
Under Setup Card header -> Select Communications Card -> TOOLSNET
SC Series Controllers
Configuration
57 / 1032

Publicidad