10.6
Fault indicator
Pos : 21.46 /Betriebs anl eitung/Leerz eile H alb @ 10\mod_1478598405587_0.doc x @ 209637 @ @ 1
Pos : 21.47 /BA N eder man Filtr ation/10 Bedienungs anl eitung/F ume Eli minator/Störungsanz eige @ 24\mod_1502276385299_2901.doc x @ 260203 @ @ 1
When the fault indicator ("STOP" key (red)) lights up, a fault in the frequency converter
has occurred.
The fault can be reset by pressing the "STOP" key. The reset will take about 3 seconds.
Subsequently the machine/plant can be restarted (→ section "Plant start-up")
Pos : 21.48 /Betriebs anl eitung/Leerz eile H alb @ 10\mod_1478598405587_0.doc x @ 209637 @ @ 1
Pos : 21.49 /Betriebs anl eitung/Ü bers chriften/1.1/10 Bedi enungsanlei tung/Filter wec hsel anzeig e @ 24\mod_1502271908838_2901.doc x @ 260063 @ @ 1
10.7
Filter change indicator
Pos : 21.50 /Betriebs anl eitung/Leerz eile H alb @ 10\mod_1478598405587_0.doc x @ 209637 @ @ 1
Pos : 21.51 /BA N eder man Filtr ation/10 Bedienungs anl eitung/F ume Eli minator/Filter wec hs elanz eige @ 24 \mod_1502276678872_2901.doc x @ 260231 @ @ 1
A differential pressure switch monitors the condition of the filter cartridge.
The filter change indicator lights up when the minimum volume flow is no longer reached.
At the same time, an acoustic signal is emitted. The filter cartridge is very dirty and has to
be replaced.
The filter change indicator continues to stay lit after the machine/plant has been switched
off and can only be deactivated by pressing the "Filter Reset" key, if the filter cartridge
was changed before.
The acoustic signal will remain active for about 1 minute after the machine/plant has been
switched off; then it will be switched off automatically.
Pos : 21.52 /Betriebs anl eitung/Leerz eile H alb @ 10\mod_1478598405587_0.doc x @ 209637 @ @ 1
Pos : 21.53 /Betriebs anl eitung/Warns ymbole mi t Sig nal wort/WICHT IG @ 16\mod_1487254098747_2901.doc x @ 221101 @ @ 1
IMPORTANT
Pos : 21.54 /Betriebs anl eitung/Sicherheits hi nweis e/WICHT IG/Fume Elimi nator /Manuelles Ei nsc halten der Filter abr einigung @ 24\mod_1502278162623_2901.doc x @ 260259 @ @ 1
If the filter cleaning function is activated manually, it may be that the filter cartridge is
cleaned again to such a degree that the minimum volume flow is reached.
The filter cleaning operation can be started by pressing the "Filter Reset" key (about
three seconds).
A filter cleaning operation that was started manually will be active for about 15 minutes;
afterwards it will be switched off automatically.