Pos : 23.21 /Betriebs anl eitung/11 Stör ungs behebung/TABELLE: Titelzeil e C hec klis te Stör ung en @ 20\mod_1492002750700_2901.doc x @ 231449 @ @ 1
Fault
Pos : 23.22 /BA N eder man Filtr ation/11 Störungsbehebung/Fume Eli minator/Chec klis te: Abs augl eistung z u hoch (Kontrollleuc hte Filterwec hs el leuc ht et nic ht) @ 24\mod_1502282344019_2901.doc x @ 260483 @ @ 1
7
Suction power is too high
(indicator lamp Filter
Change is not lit)
EN
Pos : 23.23 /BA N eder man Filtr ation/11 Störungsbehebung/Fume Eli minator/Chec klis te: Kontrolll euc hte Filter wechs el l euc htet b ei nor maler Absaugleistung @ 24\mod_1502282541696_2901.doc x @ 260511 @ @ 1
8
Indicator lamp Filter
Change is lit despite
normal suction power
Pos : 23.24 / BA N eder man Filtr ation/11 Störungsbehebung/Fume Eli minator/Chec klis te: Filterabreinig ung r einigt ni c ht ric htig oder gar nicht ab @ 24\mod_1502282705352_2901.doc x @ 260539 @ @ 1
9
Filter cleaning function is
not cleaning properly or
not at all
Pos : 23.25 /BA N eder man Filtr ation/11 Störungsbehebung/Fume Eli minator/Chec klis te: Bei m Abr einigen der Filter patrone @ 24\mod_1502283085365_2901.doc x @ 260567 @ @ 1
10 Dirt particles leak out of
the machine/plant or the
connected exhaust
element while the filter
cartridge is being
cleaned
Pos : 23.26 /BA N eder man Filtr ation/11 Störungsbehebung/Fume Eli minator/Chec klis te: Bei m Abs augen tr eten Sc hmutz parti kel aus der Luftaustritts öffnung a us @ 24\mod_1502283658873_2901.doc x @ 260595 @ @ 1
11 Dirt particles leak out of
the air outlet during the
extraction phase
Pos : 24 /Betri ebs anleitung/----- Seitenumbruc h ----- @ 10\mod_1478587717206_0.doc x @ 209487 @ @ 1
112
Possible causes
•
Potentiometer setting is too
high
•
Frequency converter is
running in the emergency
program
•
Defective potentiometer
•
Defective differential
pressure switch
•
Compressed air supply is
not connected
•
Setting for the operating
pressure is too low
•
Filter cartridge is not
inserted properly
•
Filter cartridge is clogged
•
Defective differential
pressure switch
•
Defective solenoid valve
•
Setting for the operating
pressure is too low
•
Locking clips of the cover
are loose
•
Filter cartridge is not
inserted properly
•
Filter cartridge is damaged
•
Filter cartridge is not
inserted properly
•
No filter cartridge is inserted •
Action
•
Set potentiometer to a lower value
•
Pull mains plug for about 45 seconds and
then plug in again
•
Replace the potentiometer
•
Replace the differential pressure switch
•
Connect the compressed air supply
•
Correct the operating pressure (→ section
"Operating pressure and compressed
air quality")
•
Insert the filter cartridge correctly
•
Replace the filter cartridge
•
Replace the differential pressure switch
•
Replace the solenoid valve
•
Correct the operating pressure (→ section
"Operating pressure and compressed
air quality")
•
Close locking clips correctly
•
Insert the filter cartridge correctly
•
Replace the filter cartridge
•
Insert the filter cartridge correctly
Insert the filter cartridge