Fault
Pos : 23.22 /BA N eder man Filtr ation/11 Störungsbehebung/Fume Eli minator/Chec klis te: Abs augl eistung z u hoch (Kontrollleuc hte Filterwec hs el leuc ht et nic ht) @ 24\mod_1502282344019_2901.doc x @ 260483 @ @ 1
7
Suction power is too high
(indicator lamp Filter
Change is not lit)
EN
Pos : 23.23 /BA N eder man Filtr ation/11 Störungsbehebung/Fume Eli minator/Chec klis te: Kontrolll euc hte Filter wechs el l euc htet b ei nor maler Absaugleistung @ 24\mod_1502282541696_2901.doc x @ 260511 @ @ 1
8
Indicator lamp Filter
Change is lit despite
normal suction power
Pos : 23.24 / BA N eder man Filtr ation/11 Störungsbehebung/Fume Eli minator/Chec klis te: Filterabreinig ung r einigt ni c ht ric htig oder gar nicht ab @ 24\mod_1502282705352_2901.doc x @ 260539 @ @ 1
9
Filter cleaning function is
not cleaning properly or
not at all
Pos : 23.25 /BA N eder man Filtr ation/11 Störungsbehebung/Fume Eli minator/Chec klis te: Bei m Abr einigen der Filter patrone @ 24\mod_1502283085365_2901.doc x @ 260567 @ @ 1
10 Dirt particles leak out of
the machine/plant or the
connected exhaust
element while the filter
cartridge is being
cleaned
Pos : 23.26 /BA N eder man Filtr ation/11 Störungsbehebung/Fume Eli minator/Chec klis te: Bei m Abs augen tr eten Sc hmutz parti kel aus der Luftaustritts öffnung a us @ 24\mod_1502283658873_2901.doc x @ 260595 @ @ 1
11 Dirt particles leak out of
the air outlet during the
extraction phase
Pos : 24 /Betri ebs anleitung/----- Seitenumbruc h ----- @ 10\mod_1478587717206_0.doc x @ 209487 @ @ 1
112
Possible causes
Potentiometer setting is too
high
Frequency converter is
running in the emergency
program
Defective potentiometer
Defective differential
pressure switch
Compressed air supply is
not connected
Setting for the operating
pressure is too low
Filter cartridge is not
inserted properly
Filter cartridge is clogged
Defective differential
pressure switch
Defective solenoid valve
Setting for the operating
pressure is too low
Locking clips of the cover
are loose
Filter cartridge is not
inserted properly
Filter cartridge is damaged
Filter cartridge is not
inserted properly
No filter cartridge is inserted •
Action
Set potentiometer to a lower value
Pull mains plug for about 45 seconds and
then plug in again
Replace the potentiometer
Replace the differential pressure switch
Connect the compressed air supply
Correct the operating pressure (→ section
"Operating pressure and compressed
air quality")
Insert the filter cartridge correctly
Replace the filter cartridge
Replace the differential pressure switch
Replace the solenoid valve
Correct the operating pressure (→ section
"Operating pressure and compressed
air quality")
Close locking clips correctly
Insert the filter cartridge correctly
Replace the filter cartridge
Insert the filter cartridge correctly
Insert the filter cartridge