Pos : 23.13 /Betriebs anl eitung/11 Stör ungs behebung/TABELLE: Titelzeil e C hec klis te Stör ung en @ 20\mod_1492002750700_2901.doc x @ 231449 @ @ 1
Fault
Pos : 23.14 /BA N eder man Filtr ation/11 Störungsbehebung/Fume Eli minator/Chec klis te: Maschi ne/Anlag e l ässt sich nic ht ei nsc halten (Betri eb leuchtet nicht) (Nr. 1) @ 24\mod_1502280741689_2901.doc x @ 260315 @ @ 1
1
Machine/plant can't be
switched on (indicator
lamp Operation is not lit)
Pos : 23.15 /BA N eder man Filtr ation/11 Störungsbehebung/Fume Eli minator/Chec klis te: Maschi ne/Anlag e l ässt sich nic ht ei nsc halten (Betri eb leuchtet) @ 24\mod_1502281076212_2901.doc x @ 260343 @ @ 1
2
Machine/plant can't be
switched on (indicator
lamp Operation is lit)
Pos : 23.16 /BA N eder man Filtr ation/11 Störungsbehebung/Fume Eli minator/Chec klis te: Maschi ne/Anlag e sc halten nic ht auto ei n ( Betrieb leuc htet nic ht) @ 24\mod_1502281279893_2901.doc x @ 260371 @ @ 1
3
Machine/plant doesn't
turn on automatically
(indicator lamp
Operation is not lit)
Pos : 23.17 /BA N eder man Filtr ation/11 Störungsbehebung/Fume Eli minator/Chec klis te: Maschi ne/Anlag e sc halten nic ht auto ei n ( Betrieb leuc htet) @ 24\mod_1502281515424_2901.doc x @ 260399 @ @ 1
4
Machine/plant doesn't
turn on automatically
(indicator lamp
Operation is lit)
Pos : 23.18 /BA N eder man Filtr ation/ 11 Störungsbehebung/Fume Eli minator/Chec klis te: Abs augl eistung z u geri ng (Kontrollleuc hte Filterwec hs el leuc htet nic ht) @ 24\mod_1502281652295_2901.doc x @ 260427 @ @ 1
5
Insufficient suction power
(indicator lamp Filter
Change is not lit)
Pos : 23.19 /BA N eder man Filtr ation/11 Störungsbehebung/Fume Eli minator/Chec klis te: Abs augl eistung z u geri ng (Kontrollleuc hte Filterwec hs el leuc htet) @ 24 \mod_1502282220939_2901.doc x @ 260455 @ @ 1
6
Insufficient suction power
(indicator lamp Filter
Change is lit)
Pos : 23.20 /Betriebs anl eitung/----- Seitenumbr uch ----- @ 10\mod_1478587717206_0.doc x @ 209487 @ @ 1
Possible causes
•
Mains plug is not plugged in •
•
No voltage on the socket
outlet
•
Defective fuse
•
Frequency converter or
control is switched to fault
•
Mains plug is not plugged in •
•
No voltage on the socket
outlet
•
Sensor cable is not
connected
•
Frequency converter or
control is switched to fault
•
Sensor cable is not
connected
•
Sensor cable is not
connected to the ground
cable
•
Potentiometer setting is too
low
•
Cover of the filter cartridge
is not closed properly
•
Frequency converter is
running in the emergency
program
•
Defective potentiometer
•
Saturated filter cartridge
•
Defective differential
pressure switch
•
Suction hose is kinked or
damaged
•
Saturated filter cartridge
Action
Plug in the mains plug
•
Apply voltage
•
Change the fuse
•
Pull mains plug for about 45 seconds and
then plug in again
Plug in the mains plug
•
Apply voltage
•
Connect the sensor cable
•
Pull mains plug for about 45 seconds and
then plug in again
•
Connect the sensor cable
•
Connect the sensor cable to the ground
cable
•
Set the potentiometer higher
•
Close the cover properly
•
Pull mains plug for about 45 seconds and
then plug in again
•
Replace the potentiometer
•
Replace the filter cartridge
•
Replace the differential pressure switch
•
Replace the suction hose
•
Replace the filter cartridge