Descargar Imprimir esta página

Champion Power Equipment 97001i-P-EU Manual Del Operador página 16

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 191
97001i-P-EU
4. Using a funnel, add up to 37.2 fl. oz. (1100 ml) of oil. DO NOT
OVERFILL. Replace oil fill cap/dipstick and secure cover.
When using the dipstick to check oil level, DO NOT screw in
the dipstick while checking, simply rest it against the top of
the port.
As a general rule oil is full when it can be seen visually on the
middle to upper threads of the port. Do Not angle or tip the
generator when adding oil.
5. Check engine oil level before every use and add as needed.
MAX
MAX
Once oil has been added, a visual check should show oil about
1-2 threads from running out of the fill hole.
When using the dipstick to check oil level, DO NOT screw in
the dipstick while checking, simply rest it against the top of
the port.
As a general rule oil is full when it can be seen visually on the
middle to upper threads of the port. Do Not angle or tip the
generator when adding oil.
Check oil level often during the break-in period. Refer to the
Maintenance section for recommended service intervals.
NOTICE
OIL DIP STICK
OIL DIP STICK
NOTICE
NOTICE
This engine is equipped with a low oil shut-off and will stop
when the oil level in the crankcase falls below the threshold
level.
The first 5 hours of run time are the break-in period for the
unit. During the break in period stay at or below 50% of the
running watt rating and vary the load occasionally to allow
stator windings to heat and cool. Adjusting the load will also
cause engine speed to vary slightly and help seat piston rings.
After the 5 hour break-in period, change the oil.
Synthetic oil may be used after the 5 hour initial break-in
period. Using synthetic oil does not decrease the recommended
oil change interval. Full synthetic 5W-30 oil will aid in starting
in cold ambient < 41º F (5º C) temperatures.
Add Fuel
Petrol vapors are highly flammable and extremely explosive.
DO NOT light or smoke cigarettes. Fire or explosion can cause
severe burns or death.
Only fill or drain fuel outdoors in a well-ventilated area. DO
NOT pump petrol directly into the generator. Use an approved
container to transfer the fuel to the generator.
Never use a petrol container, fuel tank, or any other fuel item
that is broken, cut, torn or damaged.
DO NOT overfill the fuel tank. Always keep fuel away from
sparks, open flames, pilot lights, heat and other sources of
ignition.
Use clean, fresh, regular unleaded petrol with a minimum octane
rating of 85 and an ethanol content of 10% or less by volume.
DO NOT mix oil with petrol.
1. Remove the fuel cap.
16
ASSEMBLY
CAUTION
A
NOTICE
NOTICE
DANGER
A

Publicidad

loading