Important: The 12V DC outlet is ONLY to be used with supplied
accessories and other commercially available 12V DC automotive
style plugs. Be sure all electric devices including the lines and
plug connections are in good condition before connection to the
generator.
A
Do Not use both 230v AC and 12v DC at the same time
otherwise you could damage the generator or equipment
resulting in voiding your warranty.
A
Do not start the vehicle while the battery charging cable is
connected and the generator is running. It will not give the
battery a boost of power. The vehicle or the generator may
be damaged. Charge only vented wet lead acid batteries.
Other types of batteries may burst, causing personal injury or
damage.
Be sure all electric devices including the lines and plug
connections are in good condition before connection to the
generator.
Stopping the Engine: No ATS or ATS on
Manual Mode
Manual Stop
1. Turn off and unplug all electrical connected loads. Never start
or stop the generator with electrical devices plugged in or
turned on.
2. Let the generator run at no-load for several minutes to
stabilize internal temperatures of the engine and generator.
3. Press the Start/Stop button.
CAUTION
WARNING
NOTICE
4. Turn the fuel dial to the "OFF" position.
Important: Always ensure that the Start/Stop button is "OFF" and
not illuminated and fuel valve is in the "OFF" position when the
generator will not be used for an extended period of time.
Remote Stop
1. Press the "STOP" button on the remote.
Engine will shut off but the Start/Stop button will remain in
"STANDBY" mode for 24 hours and fuel dial will remain in the
"ON" position waiting for the next start instruction.
To completely shut down the generator, make sure the Start/Stop
button is in "OFF" mode and no longer flashing green and fuel dial
is turned to "OFF" position when the generator will not be used for
an extended period of time
Battery power is drawn while the generator is in standby mode
(Start/Stop button flashing green).The generator will stay in
standby mode for 24 hours if shut down using the Remote
Control. To turn standby mode off manually, push and hold the
"STOP" button on the remote control for 5 seconds or push and
hold the Start/Stop button on the control panel for 5 seconds.
The RCM will no longer consume any battery power or wait
for remote signal. This is indicated by the Start/Stop button no
longer flashing.