97001i-P-EU
6. Loosen the four cover screws and remove the maintenance
cover.
7. When starting the engine, pull the recoil cord slowly until
resistance is felt, release cord back and with one strong rapid
pull to start, this avoids any kickback or damage to the recoil
assembly. If the engine doesnt start repeat this process.
A
Rigorously or aggressively pulling the recoil cord will result in
damage to the recoil assembly and void any warranty.
8. Do not over-choke. As soon as engine starts, push the choke
button one time to set the choke to the "RUN" position. Choke
button will no longer be illuminated when in "RUN" position
9. Re-install the maintenance cover.
CAUTION
Electric Start
1. Make certain the generator is on a flat, level surface.
2. Disconnect all electrical loads from the generator. Never start
or stop the generator with electrical devices plugged in or
turned on.
3. Turn the fuel dial to the "ON" position.
4. Press the Start/Stop button to enter standby mode.The button
will flash green but the generator will not attempt to start.
5. Press the Start/Stop button a second time.The button will
now flash green and the generator will attempt to start.
There will be (6) starting attempts. After generator starts, the
button will turn solid green.
22
OPERATION