Descargar Imprimir esta página

Champion Power Equipment 97001i-P-EU Manual Del Operador página 29

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 191
97001i-P-EU
Stopping the Engine: ATS on Automatic Mode
1. When the mains power is restored, the generator will
automatically stop.(Will take approx 20 seconds)
If the engine will not be used for a period of two (2) weeks or
longer, please see the Storage section for proper engine and
fuel storage.
Moving the Generator
CAUTION
A
– NEVER lift or carry the generator using the folding handle.
– NEVER tilt sideways while moving the generator.
– ALWAYS place the generator on its wheels in the upright
position.
– ALWAYS turn the generator off and ensure the fuel valve is
closed.
– ALWAYS make sure engine and muffler are cooled down
before the generator can be handled safely (typically 15-30
minutes).
WARNING
A
Failure to follow these instructions carefully could result in
personal injury or damage to the generator resulting in voiding
your warranty
WARNING
A
The folding handle is not long enough to hold and walk with a
full stride when moving the generator. Always side step as you
walk to avoid injury to your heels and/or feet. Failure to follow
these instructions could result in personal injury or damage to
the generator.
1. Begin by raising the folding handle, found on opposite side of
wheels.
2. Using the handle, tilt the end of the generator slightly off the
ground until balanced on the wheels.
NOTICE
3. While maintaining balance, roll the generator to the desired
location.
Operation at High Altitude
The density of air at high altitudes is lower than at sea level.
Engine power is reduced as the air mass and air-fuel ratio
decrease. Engine power and generator output will be reduced
approximately 3½% for every 1000 ft. of elevation above sea level.
At high altitudes increased exhaust emissions can also result due
to the increased enrichment of the air fuel ratio. Other high altitude
issues can include hard starting, increased fuel consumption and
spark plug fouling.
To alleviate high altitude issues other than the natural power
loss, CPE can provide a high altitude carburetor main jet. The
alternative main jet and installation instructions can be obtained
by contacting our Technical Support Team. Installation instructions
are also available in the Technical Bulletin area of the CPE website.
The part number and recommended altitude range for the
application of the high altitude carburetor main jet is listed in the
following table.
In order to select the correct high altitude main jet it is necessary
to identify the carburetor model. For this purpose, a code is
stamped on the side of the carburetor. Select the correct high
altitude jet part number corresponding to the carburetor code
found on your particular carburetor.
Carb. Code High Alt. Jet Part Number
16100-
16161-Z520110-00A0
Z1E0611-
16161-Z100110-00A0
00A0
29
OPERATION
EN
Altitude Range
3000ft. (914m)
6000ft. (1829 m)

Publicidad