Descargar Imprimir esta página

Champion Power Equipment 97001i-P-EU Manual Del Operador página 31

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 191
97001i-P-EU
4. Remove the oil drain plug by turning it counter clockwise.
5. Ensure the oil drain hose is lower than the engine and allow
the oil to drain completely into an appropriate container.
6. Replace the oil drain plug.
7. Add oil according to Add Engine Oil in Assembly section.
Recommended 10W30 DO NOT OVERFILL. Oil not included for
routine maintenance.
8. Reinstall the maintenance cover.
9. Dispose of used oil at an approved waste management
facility.
Once oil has been added, on flat level surface as a general rule
oil should be visible about 1-2 threads from top of the oil port
hole. If using the dipstick to check oil level, DO NOT screw in
the dipstick while checking simply rest it against the top of the
port and take reading.
DRAIN PLUG
DRAIN TUBE
NOTICE
Cleaning and Adjusting the Spark Plug
1. Loosen the four cover screws and remove the maintenance
cover.
2. Remove the spark plug cable from the spark plug.
3. Use a spark plug socket tool (included), or a
13/16 in. (21 mm) socket (not included) to remove the plug.
4. Inspect the electrode on the plug. It must be clean and not
worn to produce the spark required for ignition.
5. Make certain the spark plug gap is
0.028-0.031 in. (0.7-0.8 mm).
6. Refer to the spark plug types in Specifications when replacing
the plug.
7. Firmly re-install the plug.
8. Attach the spark plug cable to the spark plug.
9. Reinstall the maintenance cover.
31
MAINTENANCE
SPARK PLUG GAP
EN

Publicidad