2. Slowly add petrol to the tank. Tank is full when petrol reaches
red circle on screen. DO NOT OVERFILL. Petrol can expand
after filling. A minimum of ¼ in. (6.4 mm) of space left in the
tank is required for petrol expansion, although more than ¼
in. (6.4 mm) is recommended. Petrol can be forced out of the
tank as a result of expansion if overfilled, and can affect the
stable running condition of the generator.
3. The approximate fuel level is shown on the fuel gauge on top
of the fuel tank.
Empty
4. Screw on the fuel cap and wipe away any spilled fuel.
CAUTION
A
Use unleaded petrol with a minimum octane rating of 85 and
an ethanol content of 10% or less by volume.
DO NOT light cigarettes or smoke when filling the tank.
DO NOT mix oil and petrol, this is a four stroke engine with
separate oil and petrol.
DO NOT overfill the tank. Fill tank to approximately ¼ in.
(6.4 mm) below the top of the tank to allow for petrol
expansion.
DO NOT pump petrol directly into the generator at the pump.
Use an approved fuel container to transfer the petrol to the
generator.
DO NOT fill fuel tank indoors, in garages, in sheds or in any out
building.
DO NOT fill tank when the engine is running or hot, always
allow engine to cool minimum 30 mins before refueling.
Pouring petrol too fast through the fuel screen may result in
petrol splashing over the generator and operator while filling.
The generator engine works well with 10% or less ethanol
blended petrol. When using ethanol-petrol blends there are
some issues worth noting:
– Ethanol-petrol blends can absorb more water than petrol
alone.
– These ethanol blends can eventually separate, leaving
water or a watery goo in the tank, fuel valve and
carburetor. The compromised petrol can be drawn into the
carburetor and cause damage to the engine and/or create
potential hazards.
– If a fuel stabilizer is used, confirm that it is formulated to
work with ethanol-petrol blends.
– Any damages or hazards caused by using ethanol blended
Full
petrol higher than 10% by volume, improperly stored
petrol, and/or improperly formulated stabilizers, are not
covered by manufacturer's warranty.
It is advisable to always shut off the petrol supply and run the
engine to starvation after each use. See Storage instructions
for extended non-use.
Grounding
It is recommended your generator is properly connected to an
appropriate ground to help prevent electric shock.
Failure to properly ground the generator can result in electric
shock.
A ground terminal connected to the frame of the generator has
been provided (see Controls and Features for terminal location).
For remote grounding, connect a length of heavy gauge
(12 AWG minimum) copper wire between the generator ground
terminal and a copper rod driven into the ground. We strongly
recommend that you consult with a qualified electrician to ensure
compliance with local electrical codes.