number of hoists x hoist's nominal power rating [kW] x 3). The
operator must earth the generator. The earthing function must be
tested (isolation test).
The existing connection used must be equipped with a 30 mA
safety switch (FI or RCD) and overload protection (automatic
circuit breaker with K- feature). The starting current is three times
the nominal current of the hoist.
Three-phase current: 400 V (3P + N + PE), 50 Hz
Alternating current: 230 V (P + N + PE), 50 Hz
The longer the power supply cable, the larger the cable cross-
section must be.
Secure hanging cables with cable ties (1), see Fig. 20.
Use heavy duty rubber lines with support elements.
Determining the required cable cross-section:
Determine the code letter (e.g. 'C') using Table 5. On hoists
with two speeds the maximum rope speed is the determin-
ing factor.
In Table 6 determine the cable cross-section required for the
code letter.
m/min
400 V
X 300 P
9
A
X 400 P
18
A
X 500 P
9
A
X 520 P
18
B
L 500 P
X 600 P
9
B
X 620 P
18
C
X 820 P
X 1030 P
9
B
18
C
X 2050 P
6
C
12
D
X 2058 P
18
E
Table 5
G1035.2 - 11/2014
one hoist
two hoists
230 V
400 V
230 V
C
A
E
-
B
-
E
B
F
-
D
-
D
D
F
-
E
-
E
D
F
-
F
-
-
F
-
-
F
-
-
F
-
Code letter
20 m
A
1.5
B
1.5
C
1.5
D
1.5
E
1.5
F
1.5
G
2.5
Table 6
Mount the wire rope
DANGER!
Danger of severe accidents caused by incorrect anchor-
ing or damaged ropes!
Might result in severe injuries or even death!
The wire rope must hang free.
The wire rope must never run over an edge!
Risk of injury through stabs and cuts!
Broken wires in the wire rope can result in protruding wires!
Protruding wires can cut or stab through safety gloves!
Wear suitable leather protective gloves when working
with wire ropes.
Never let the wire rope run through your hands.
Danger of crushing or being pulled in!
When threading the wire rope in there is a risk of fingers or
the entire hand being pulled in with the wire rope or being
crushed on the pulleys and rope guides!
Never touch the wire rope whilst the hoist is in operation!
Do not reach into the inlet or outlet of the hoist.
Maintain a suitable distance from the wire rope.
Watch out for rope loops.
ATTENTION!
Incorrect assembly!
Damage to the hoist possible!
The unloaded side of the hoist may be loaded with a
maximum of 100 kg (e.g. via the wire rope pretension-
ing).
Note:
If the anchoring point for the wire rope is located above the hoist
the wire rope must be fastened before it is fed into the hoist.
Operation and Installation Manual
Cable cross-section [mm²]
for cable lengths up to...
50 m
100 m
200 m
1.5
1.5
1.5
1.5
1.5
2.5
1.5
2.5
4
2.5
4
6
2.5
4
10
4
10
16
6
10
16
EN-13