Safety
Product
Mechanical
Information
Information
Installation
Trip
SMARTCARD trip: SMARTCARD attempting to change the destination drive ratings
C.rtg
No drive rating parameters have been transferred
186
Press the red
Drive rating parameters are:
Parameter
4.05/6/7, 21.27/8/9
5.07, 21.07
5.09, 21.09
5.17, 21.12
5.23, 21.13
5.24, 21.14
5.25, 21.24
The above parameters will be set to their default values.
C.Typ
SMARTCARD trip: SMARTCARD parameter set not compatible with drive
Press the reset button
187
Ensure destination drive type is the same as the source parameter file drive type
dESt
Two or more parameters are writing to the same destination parameter
199
Set Pr xx.00 = 12001 check all visible parameters in the menus for duplication
EEPROM data corrupted - Drive mode becomes open loop and serial comms will timeout
EEF
with remote keypad on the drive RS485 comms port.
31
This trip can only be cleared by loading default parameters and saving parameters
Enc1
Drive encoder trip: Encoder power supply overload
Check encoder power supply wiring and encoder current requirement
189
Maximum current = 200mA @ 15V, or 300mA @ 8V and 5V
Enc2
Drive encoder trip: Wire break
Check cable continuity
190
Check wiring of feedback signals is correct
Check encoder power is set correctly
Replace feedback device
If wire break detection on the main drive encoder input is not required, set Pr
the Enc2 trip
Enc3
Drive encoder trip: UVW phase offset incorrect whilst running
Check the encoder signal for noise
191
Check encoder shielding
Check the integrity of the encoder mechanical mounting
Repeat the offset measurement test
Enc4
Drive encoder trip: Feedback device comms failure
Ensure encoder power supply is correct
192
Ensure baud rate is correct
Check encoder wiring
Replace feedback device
Enc5
Drive encoder trip: Checksum or CRC error
Check the encoder signal for noise
193
Check the encoder cable shielding
With EnDat encoders, check the comms resolution and/or carry out the auto-configuration Pr 3.41
Enc6
Drive encoder trip: Encoder has indicated an error
Replace feedback device
194
With SSI encoders, check the wiring and encoder supply setting
40
Electrical
Getting
Installation
Started
reset button
2.08
Standard ramp voltage
Current limits
Motor rated current
Motor rated voltage
Stator resistance
5.18
Switching frequency
Voltage offset
Transient inductance
Stator inductance
6.06
DC injection braking current
www.controltechniques.com
Running
Advanced
Menu 0
the motor
parameters
Diagnosis
Function
Unidrive SP Short Form Guide
UL Listing
Diagnostics
Appendix
Information
3.40
= 0 to disable
Issue Number: 1