Trip
SLX.Er
Solutions Module slot X trip: Solutions Module in slot X has detected a fault
Fieldbus module category
202,207,
212
Check value in Pr 15/16/17.50. The following table lists the possible error codes for the Fieldbus
modules.
Error code
52
61
65
66
67
68
69
70
71
74
98
99
SLX.HF
Solutions Module slot X trip: Solutions Module X hardware fault
200,205,
Ensure Solutions Module is fitted correctly
210
Return Solutions Module to supplier
SLX.nF
Solutions Module slot X trip: Solutions Module has been removed
Ensure Solutions Module is fitted correctly
203,208,
Re-fit Solutions Module
213
Save parameters and reset drive
Solutions Module trip: Drive mode has changed and Solutions Module parameter routing is
SL.rtd
now incorrect
Press reset.
215
If the trip persists, contact the supplier of the drive.
SLX.tO
Solutions Module slot X trip: Solutions Module watchdog timeout
203,208,
Press reset.
211
If the trip persists, contact the supplier of the drive.
t010
User trip defined in 2
10
SM-Applications program must be interrogated to find the cause of this trip
t036 to
User trip defined in 2
t038
36 to 38
SM-Applications program must be interrogated to find the cause of this trip
t040 to
User trip defined in 2
t089
40 to 89
SM-Applications program must be interrogated to find the cause of this trip
Unidrive SP Short Form Guide
Issue Number: 1
Electrical
Getting
Installation
Started
Fieldbus Option
All except DPLCAN
All
All except DPLCAN
DeviceNet, CANopen
and DPLCAN
CANopen
CANopen
DPLCAN
All
DeviceNet
All
All
All
nd
processor Solutions Module code
nd
processor Solutions Module code
nd
processor Solutions Module code
www.controltechniques.com
Running
Advanced
Menu 0
the motor
parameters
Diagnosis
Reason for fault
Control word user trip
Invalid configuration parameters.
Network loss
"Bus-Off" Node sees an excessive number of
transmission errors.
Node has not received a SYNC telegram within a
specified time - to be defined.
Node has not received the guarding telegram within the
time period specified.
Node sends a data frame and no other node
acknowledges
receipt of the frame message.
No valid Fieldbus Menu data available in the module to
download to the drive – The user may not have saved
any data, or the data save may not have been
completed successfully.
The External power supply has been lost. This trip will
only occur if the module was on line with a master when
the loss occurs. i.e. will not occur if the power supply is
not present during module initialisation.
The Solutions Module has overheated.
The Solutions Module background task has not
been completed.
Software Fault.