3.1.2 LED indicator for operating mode and mode change

DE
EN
FR
IT
Fig. 4:
The current operating mode setting is indicated by a LED.
Switching mode:
ES
X Press the MODE button until the LED lights up
X Use the "+" and "-" buttons to select the desired mode
X Press the MODE button until the LED goes out

3.1.3 LED numeric display (2 digits)

CZ
Directly after the unit has been switched on:
„ Displays the programme version of the control panel (5 seconds duration, during which the "SL" LED
lights up)
„ Displays the programme version of the generator (5 seconds duration, during which the "V" LED lights
up)
PL
„ Switches to the mode which was set when the unit was switched off.
„ Selects of the diameter / of the manual power which was set when the unit was switched off.
The unit is now ready to perform shrink fitting.
After display of the version, normal operation:
RU
„ Automatic modes (SL, N, V)
The display shows:
Before heating, the selected tool diameter in mm
During heating, the time remaining for the generator in seconds
„ Manual mode (MAN)
ZH
The display shows:
Before heating, the selected heating power as a percentage
During heating, the heating time elapsed in seconds
Fault condition:
„ In a fault condition an error number is displayed (see "Troubleshooting").
36
SL
N
V
MAN
Operating mode: Three automatic modes and one manual mode are available
Slim chucks
Standard chucks
Reinforced chucks
Manual shrink fitting