NEO P107 - Instruction manual
Adjust the force valve of the RIVKLE
Check that the pressure of the compressed air
supply is between 5.5 bar (80 psi) and 6.5 bar
(94 psi), and connect the tool.
1- Insert a 4 mm hexagonal key (supplied) into the
setting valve.
2- Screw to increase the force / Unscrew to
decrease the force.
3- By increasing the force, the black marker moves
backwards / by reducing the force, the black marker
moves forwards.
4- It is recommended that you regularly check the
force generated by the tool, using the RIVKLE
FC340 force indicator (not supplied with the tool) for
two reasons:
• Check that the RIVKLE
working properly
• Maintain the setting quality of your Böllhoff fastener.
PLEASE NOTE
The values indicated on the rule are provided for
indicative purposes only. Upon delivery, the tool is
deliberately set to minimum force. It'll therefore be
imperative that you adjust the tool for the first
commissioning. An excessive setting force may
damage the blind rivet nut's tapping or the thread
of the mandrel, or may prevent its unscrewing.
5-5 Connection to the compressed air supply
>>> Quickstart fig. 3
PLEASE NOTE
The tool is driven by compressed air at an
optimal pressure of 6 bar (87 psi). The service
pressure is between 5.5 bar (80 psi) and
6.5 bar (94 psi) at most.
Below 5.5 bar (80 psi), the tool's functioning may be
downgraded.
Use a separator device for the compressed air supply
(quick connection, valve, etc.).
We recommend using a Filter Regulator Lubricant
(FRL) reference 23659900036, on your compressed
air supply in order to optimise the life span of your
tool and to guarantee user safety.
®
NEO P107 tool
®
®
NEO P107 setting tool is
The air hose connecting the tool to the compressed
air supply must not exceed a length of 3 metres
(120 inch) in order to ensure that the tool has an
optimal life span and requires minimum maintenance.
The air hose must have an internal diameter of at least
6.4 mm (1/4"). A quick connection and/or a com-
pressed air cut-out valve must be accessible to the
user.
PLEASE NOTE
A compressed air supply which contains excessive
amounts of lubricant, water, impurities or excessive
pressure may seriously damage the tool. Do not use
oil containing silicone. We recommend setting the
lubricant flow of your FRL to 1 drop/minute.