7. Défauts, causes et remèdes
7-1 Safety guidelines in the event of failure
WARNING
Only staff with the required qualifications are authorised
to carry out repairs.In the event of a fault, immediately
shut off the tool. Correct the fault straight away. Before
starting any work, disconnect the tool from the
compressed air supply. Otherwise, you're at risk of
injury. If, during an intervention, you need to unscrew
a screwed element, take care to re-screw it correctly,
respecting the screwing torque when specified.
7-2 Troubleshooting
ISSUE
SCREWING
The tool continuously screws
No screwing
The blind rivet nut isn't in
contact with the anvil after
the screwing / difficult to
screw the blind rivet nut
TRACTION
No setting stroke
Several cycles are required
to acheive a correct setting
PROBABLE CAUSES
Unsettled Push-Pull adjustment
bush.
1- Traction bush unscrewed, worn
and/or damaged
2- Unsettled Push-Pull adjustment
bush.
3- Tool not powdered with
compressed air.
1- Mandrel thread damaged, worn.
2- Anvil poorly adjusted.
3- Blind rivet nut isn't held in the
setting axis during screwing.
1- Lack of oil in the tool.
2- The setting force is insufficient.
3- Insufficient compressed air
pressure.
4- Application thickness incompatible
with RIVKLE
®
.
1- Lack of oil in the tool.
2- Insufficient compressed air
pressure.
3- The blind rivet nut isn't
compatible with the tool's
maximum stroke.
WARNING
Injury risk !
Working with the tool entails potential risks. Always
wear safety goggles, protective gloves, close-fitting
work clothes, hearing protection and safety boots.
SOLUTIONS
Set the Push-Pull adjustment bush (Paragraph 8.5)
1- Check the traction bush, make sure that it's securely
screwed against the Push-Pull adjustment bush and that
the O-ring on the Push-Pull adjustment bush is indeed
present and in good condition, and check for any internal
wear on the traction bush.
2- Set the Push-Pull adjustment bush (Paragraph 8.5)
3- Check that the tool is correctly supplied with compressed
air in line with Böllhoff recommendations (Paragraph 8.5).
1- Change the mandrel (Paragraph 5.2). Increase the
replacement frequency.
2- Check/Adjust the position of the anvil (Paragraph 5.3).
3- Hold the blind rivet nut in the setting axis during screwing.
To assist if required, engage the first thread of the blind
rivet nut on the mandrel by hand.
1- Top up the oil using the filling bottle supplied
(Paragraph 8.4)
2- Check the setting force in the RIVKLE
the setting force set on the tool (Paragraph 5.4) / Check
the setting force of the tool using the RIVKLE
indicator / Increase the check frequency.
3- Check the service pressure (Paragraph 5.5).
4- Check that the thickness of your application is compatible
with the RIVKLE
®
, refer to the Böllhoff recommendations.
1- Top up the oil using the filling bottle supplied
(Paragraph 8.4)
2- Check the service pressure (Paragraph 5.5).
3- Check that your RIVKLE
with the blind rivet nut, refer to the Böllhoff
recommendations (Paragraph 3.4).
®
catalogue / Check
®
FC340 force
®
NEO P107 tool is compatible
EN