6. Use
6-1 Safety guidelines regarding preparation
for commissioning
DANGER
Risk of crushing and cutting !
During the screwing operations (push-pull system),
screwing the RIVKLE
®
onto the mandrel, be extremely
vigilant as an untimely triggering of the setting
cycle could cause injury.
Place your fingers at the end of the RIVKLE
the screwing operation (push-pull system), remain
vigilant throughout the screwing operation.
WARNING
Injury risk !
Working with the tool carries potential risks. Always
wear safety goggles, protective gloves, hearing
protection, close-fitting work clothes, and safety
boots.
WARNING
Only trained, qualified and experienced operators, who
have read and understood the user manual and the
risks undertaken, may use this tool. The operator must
stay vigilant and be physically capable of handling,
using and transporting the tool, whilst also complying
with the basic safety principles.
6-2 Procedures for use
>>> Quickstart fig. 5
Screwing the threaded insert (Push-Pull system)
1- Place the head side of the blind rivet nut onto
the mandrel. Push on the blind rivet nut, holding it
firmly in the tool axis, and screwing will activate
automatically (Push-Pull system).
2- Guide the blind rivet nut until it comes to a stop
on the anvil, and the screwing will stop automatically.
PLEASE NOTE
During all of the following operations, make sure
that you maintain good perpendicularity between
the nose of the tool and the application.
Setting
3- Insert the blind rivet nut screwed on the tool
into the application.
4- Press on the trigger and hold it down until the
end of the cycle.
Unscrewing
5- Once the force has been reached, the tool
automatically activate the unscrewing. Make sure
that you relieve the weight of the tool during the
unscrewing phase.
®
during
PLEASE NOTE
Do not pull on the tool during the unscrewing
phase.
The trigger must be held down during the entire
cycle. If this loosens, any setting will be non-compliant
as a result.
6- Release the trigger, the tool is ready for a new
setting cycle.
6-3 Manual unscrewing procedure
PLEASE NOTE
Sometimes, the tool may become blocked and
the automatic unscrewing won't work.
1- Identifying the manual unscrewing button
(See chapter 3.1)
2- Hold the manual unscrewing button down to start
unscrewing
3- The tool starts the unscrewing, lighten the tool
and hold it in the unscrewing axis
4- When the tool is completely clear, let go of the
manual unscrewing button.
6-4 Forced unscrewing procedure
WARNING
Before any interventions, please
disconnect your tool from
the compressed air supply.