Descargar Imprimir esta página

Angelo Po BX61G Manual De Uso página 48

Horno mixto

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 98
Alarm
Fault
No water in chamber, or water
H2O
pressure too low
No mains gas, gas pressure
E12
too low or fl ame detection
failure
Oven door opening or closure
OPE
request.
Indicates that cleaning is
CLE
required
Indicates the need for the
dEC
descaling operation.
The cooking chamber probe
E01
has failed or is not properly
connected
The product core probe is not
E02
inserted in the food or has
failed
The steam discharge probe
E03
has failed
The motor-operated valve is
E04
not positioned correctly
E05
Safety thermostat failure
GB
E06
Overload cutouts tripped
The optional vacuum probe
E08
has failed or is not properly
connected
Maximum allowed
E09
temperature in chamber
exceeded
Electrical component com-
E10
partment has overheated
E11
Electronic circuit board dia-
E13
gnostics tripped
E14
E20
Setup error
3338970_ut_GB
Remedy
Check that mains water is
present or adjust the pressure
(see "installation manual"); if
the problem persists inform
the after-sales service
Press reset button (the button
may have to be pressed
several times); if the problem
persists inform the after-sales
service
Open or close the oven door
Inform the after-sales service if
this message continues to be
displayed
Clean
Perform descaling
Inform the after-sales service
Check the position of the pro-
duct core probe or inform the
after- sales service if it is faulty
Inform the after-sales service
Switch on the oven again and
if the problem persists inform
the after-sales service
Inform the after-sales service
Inform the after-sales service
Press the "Reset" button
Inform the after-sales service
The oven solves the problem
on its own
Inform the after-sales service
Inform the after-sales service
- 20 -
Notes
Convection cooking cycles
can still be carried out
Stop cooking if this message is
repeated more than once
The cooking cycle does not
start until the door has been
opened or closed as required
The oven's functions are ena-
bled so cooking cycles can be
carried out
The oven's functions are ena-
bled so cooking cycles can be
carried out
The oven's functions are disa-
bled so no cooking cycles can
be carried out
Cooking cycles with product
core probe cannot be carried
out
Convection and steam coo-
king cycles can still be carried
out
Convection and steam coo-
king cycles can still be carried
out
The oven's functions are disa-
bled so no cooking cycles can
be carried out
The oven's functions are disa-
bled so no cooking cycles can
be carried out
Disconnect and reconnect the
vacuum probe before starting
the cooking cycle.
If the problem persists, call the
after-sales service
The oven's functions are disa-
bled so no cooking cycles can
be carried out
The oven's functions are ena-
bled so cooking cycles can be
carried out
The oven's functions are disa-
bled so no cooking cycles can
be carried out
The oven's functions are disa-
bled so no cooking cycles can
be carried out
ENGLISH

Publicidad

loading

Este manual también es adecuado para: