61000-3-2
Method: This test consists on the measurement of harmonics components of the input current which may be produced by
equipment having an input current up to and including 16 A per phase, and intended to be
connected to public low-voltage distribution systems. The equipment is tested under specified conditions of
Laboratory Parameters
Ambient Temperature
Relative Humidity
Equipment mode
Supplementary information: This 10W equipement is compliant for harmonic current emissions without measurement. (p<75W)
1.9 Test Conditions and Results - Limitation of Voltage Fluctuations and Flicker
61000-3-3
TEST: Limitation of Voltage Fluctuations And Flicker (IEC 61000-3-3: - use latest edition)
Method: The test circuit consists of a test supply voltage, reference impedance, the equipment under test
and a flicker meter compliant with lEC 60868 The equipment shall be tested in the condition in which the
Laboratory Parameters
Ambient Temperature
Relative Humidity
Equipment mode
Supplementary information: This equipment is unlikely to produce voltage fluctuation and flicker. This equipment is compliant
without
Electromagnetic emissions
1.8 Test Conditions And Results - Limits for Harmonic Current Emissions
TEST: Limits for Harmonic current emissions (IEC 61000-3-2: - use latest edition)
operation.
Required prior to the test
Classification of Equipment
manufacturer supplies it.
Required prior to the test
EUT configurations mode
15 to 35 °C
30 to 60 %
Power interface mode
EUT configurations mode
Operation mode
15 to 35 °C
30 to 60 %
Power interface mode
Operation mode
177
Verdict
P
During the test
-
-
230V 5OHz
2
2
Class A
Verdict
P
During the test
-
-
230V 5OHz
2
2