SPIDER MAX 500
9.
INJECTION CENTRAL UNIT SUPPLY CIRCUIT
9.1
Constant power supply circuit check (12V – with the key on the "OFF" position)
The injection central unit supply is important in order to control the stepper motor.
Failure in the supply prevents both ignition and injection.
In case a problem in the central unit occurs, the diagnostic multimeter generates the following warning message:
"CENTRAL UNIT IS NOT RESPONDING".
Perform the check as follows:
- Lift the side stand.
- Position the key switch on the "ON" position.
- Position the emergency switch on "RUN".
- Verify whether the injection led flashes for 5 seconds.
The injection central
unit is receiving
power
F. 11
All manuals and user guides at all-guides.com
Check the 3A no. 8 fuse operation.
Remove the short circuit cause
and replace the fuse.
50
12/04
Check digital
instrument and
supply.
B
CENTRAL UNIT IS NOT
RESPONDING
CHECK CONNECTIONS
PARAMETERS
1/4