SPIDER MAX 500
12.2 Pump supply circuit
The central unit controls the pump operation when the following conditions occur:
- move the key switch to the "ON" position and the emergency switch on "RUN" and lift the side stand. The pump is
supplied for 2 seconds.
- when the engine rpm/ speed signal is on.
Continuous supply.
The initial time is necessary to bleed the system, especially in case of a stop at warm engine.
In these conditions, the fuel, modified by the boiling is mixed with the fuel contained in the tank.
During the motorcycle use, the pump operation is subordinate to the motor revolution.
12.3 Circuit check
Follow the above instructions to check the circuit:
- Lift the side stand.
- Position the key switch on the "ON" position.
Try to start the engine. Make sure that the engine
revolution occurs together with the pump rotation.
No anomaly in the electrical supply
Try to start the engine. Select the menu from the function "ERRORS".
Check for any possible anomaly.
Pump control relay circuit
malfunctioning.
H.T. coil
Stepper motor
Pump relay
Relay fan
Auto-adaptation parameters
RAM memory
Errors
2/3
All manuals and user guides at all-guides.com
Connect the diagnostic multimeter to the
motorcycle system.
A
M
60
12/04
- Position the emergency switch on "RUN".
- The pump rotation is monitored for two seconds.
The pump does not rotate or
keeps rotating.
Malfunctioning of the:
- injector
- H.T. coil
- signal panel
Throttle
H.T. coil
Pressure
Stepper motor
Water temperature
Pump relay
Air temperature
Relay fan
Battery voltage
Auto-adap. param.
Injector
RAM memory
Errors
1/3 A
Errors
B
2/3 A