Malaguti SPIDER MAX GT 500 Manual Diagnóstico página 247

Tabla de contenido

Publicidad

SPIDER MAX 500
23. REV. COUNTER CONTROL CIRCUIT
TERMINALS
3 - 23
23.1 Circuit diagram
Dashboard
Dashboard
connector
Sch. 14
The digital dashboard receives the engine rpm signal from the injection central unit.
To check the rev. counter and its control circuit, proceed as follows:
Connect the diagnostic multimeter. Move the key switch to the "ON", the
emergency switch to "RUN" and lift the side stand.
Select the menu from the "ACTIVE DIAGNOSTICS" function and enable the rev. counter
diagnosis. Make sure that the rev. Counter gets to 3500 rpm and then back to zero.
The rev. counter control operates properly.
All manuals and user guides at all-guides.com
CONDITIONS
- key switch on the "ON" position
- emergency stop on "RUN"
- side stand lifted
- engine not running
1B
3
Parameters
Immobilizer
Errors
Delete errors
Active diagnostics
CO calibration
Main
121 12/04
CENTRAL UNIT
23
N
Fuel pump relay
H.T. coil
Stepper motor
Rev. counter
Injector
Fan relay
5/8
Diagnosis
Connect the testing wiring to the
system connector but do not connect
the central unit.
B
STANDARD
9 ÷ 10 Volt
4/6