SPIDER MAX 500
The errors that can be detected by the autodiagnostic system may concern the following system circuits or central unit
sections:
- throttle valve position signal;
- room pressure signal;
- coolant temperature signal;
- Intake air temperature signal;
- Incorrect battery voltage;
- Injector and corresponding circuit;
- H.T. coil and corresponding circuit;
- Stepper motor and corresponding circuit;
- pump relay circuit;
- Fan relay circuit;
- RAM memory;
- ROM memory;
- EEPROM;
- Microprocessor
- Signal panel (signal for engine rpm - speed - unstable cycle).
The underlined anomalies always cause the engine to stop.
In all other cases, the engine continues running, managed by the data bases.
11.2 Deletion of stored anomalies
After correcting the anomaly connect the diagnostic multi-
meter.
Select the menu from the "DELETE ERRORS" function.
Press OK and follow the instructions.
After a test race, check for the anomaly recurrence.
For troubleshooting guide, refer to the corresponding chapter
sections.