ABB ProcessMaster FEP300 Manual Del Usuario página 104

Ocultar thumbs Ver también para ProcessMaster FEP300:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 219
5.3
Preparing the signal and magnet coil cable in the case of transmitters with single-compartment
housing
Fig. 29: Transmitter side, dimensions in mm (inch)
1 Ground wire
2 Wire mesh shield (D173D027U01 only)
4 Twisted wire mesh shield (D173D027U01 only)
Terminal
Description, wire color
M1
Magnet coil, brown
M2
Magnet coil, red
D1
Data line, orange
D2
Data line, yellow
SE
Shield
3
Measurement potential, green
2S
Shield for E2
E2
Signal line, blue
E1
Signal line, violet
1S
Shield for E1
CI/FEX300/FEX500-X1
M1 M2 D1 D2
1
2
4
M1 M2 D1 D2
5
6
1
5 Foil shield continuity wire D1, D2
(D173D031U01 only)
6 Foil shield D1, D2 (D173D031U01 only)
FEX300, FEX500
Electrical connections
SE 3 2S E2 E1 1S
D173D027U01
SE 3 2S E2 E1 1S
D173D031U01
Length in mm (inch)
70 (2.76)
70 (2.76)
70 (2.76)
70 (2.76)
-
70 (2.76)
60 (2.36)
60 (2.36)
60 (2.36)
60 (2.36)
G01323
EN - 31

Publicidad

Tabla de contenido
loading

Tabla de contenido