5.5.2

Plastic terminal box in the case of ProcessMaster

Connections can only be made with the power supply switched off.
The unit must be grounded. The flowmeter sensor must be connected to the transmitter via the
signal / magnet coil cable.
Fig. 34
1 Ground wire
2 Wire mesh shield (D173D027U01 only)
4 Twisted wire mesh shield (D173D027U01 only)
Terminal
Description, wire color
M1
Magnet coil, brown
M2
Magnet coil, red
D1
Data line, orange
D2
Data line, yellow
PE
Shield
3
Measurement potential, green
S2
Shield for E2
E2
Signal line, blue
E1
Signal line, violet
S1
Shield for E1
CI/FEX300/FEX500-X1
S1 E1 E2 S2 3 D1 D2 PE M2 M1
1
2
4
5
D173D027U01
FEX300, FEX500
S1 E1 E2 S2 3 D1 D2 PE M2 M1
1
5
5 Ground terminal
6 Foil shield D1, D2 (D173D031U01 only)
7 Foil shield continuity wire D1, D2 (D173D031U01
only)
Electrical connections
6 7
D173D031U01
G01324