ECL-76, ECL-102
7.2
DC-Kit1 with FreshJet1100
Roof air conditioner: Dometic FreshJet 1100
Circuit diagram: fig. 2, page 4
Charging current distributor: ECL-76
Inverter: PerfectPower PP1002
➤ Install inverter remote control C (membrane button) in an easily-accessible place and
connect its cable to the inverter.
NOTE
I
Observe also the instructions in the scope of delivery of the sensing cable.
➤ Remove the FreshJet's outlet panel.
➤ Use the two-wire sensing cable to link the ECL-76 to the 6-pole pin strip socket (item
no. 4441300881) of the air conditioner (fig. g, page 18).
7.3
DC-Kit2 with Dometic CA2500/B2200/B1600 Plus
Roof air conditioner:
– Dometic CA2500
– B1600 Plus/B2200
Circuit diagram:
– CA2500: fig. 3, page 5
– B1600 Plus/B2200: fig. 5, page 7
Charging current distributor: ECL-102
Inverter: PP2002
➤ Install inverter remote control C (membrane button) in an easily-accessible place and
connect its cable to the inverter.
Dometic CA2500
➤ Remove the CA2500's outlet panel.
➤ Connect the charging current distributor to the air conditioner using the two-wire uni-
versal connection cable (on/off cable, item no. 4441300124).
➤ Connect the wire sleeves of the universal connection cable to contacts 12 and 13
on the charging current distributor.
➤ A cable leading out provides the connection to the circuit board (fig. j, page 19). Sev-
er this cable and join the resulting cable ends to the universal connection cable.
EN
Connection
69