Connection
7
Connection
NOTICE!
A
Make sure that you run the on/off cable away from live power cables.
WARNING!
!
To prevent short circuits, always disconnect the negative terminal of the ve-
hicle battery before working on the vehicle electrical system.
If the vehicle has an additional battery, its negative terminal must also
be disconnected.
The cable cross section for the connection between the starter battery, power
relay and consumer battery must not be less than 16 mm² for the ECL-76 and
25 mm² for the ECL-102. Also check that the cable between the negative
terminal of the consumer battery and vehicle chassis is at least 16 mm² and
25 mm² respectively – you might need to replace the cable provided with a
thicker one. The minimum cable cross sections are listed in the following
table.
The table shows the combinations possible of roof air conditioners, charging current dis-
tributors and inverters and the necessary cable cross sections of the access leads:
Roof air
conditioner
Dometic CA1000
Dometic CA1000
Dometic CA2500
Dometic CA2500
Dometic B1600
Dometic B1600
Dometic B1600
Plus
Dometic B1600
Plus
Dometic B2200
Dometic B2200
66
Charging current
distributor
(item no.)
ECL-76
ECL-102
ECL-102
ECL-102
ECL-102
ECL-102
ECL-102
ECL-102
ECL-102
ECL-102
Inverter
(item no.)
PerfectPower PP1002
SinePower SP1500
(MSK1500-012)
PerfectPower PP2002
SinePower SP1500
(MSK1500-012)
PerfectPower PP2002
SinePower SP1500
(MSK1500-012)
PerfectPower PP2002
SinePower SP1500
(MSK1500-012)
PerfectPower PP2002
SinePower SP1500
(MSK1500-012)
ECL-76, ECL-102
Cable cross
section
16 mm
minimum
2
25 mm
minimum
2
25 mm
minimum
2
25 mm
minimum
2
25 mm
minimum
2
25 mm
minimum
2
25 mm
minimum
2
25 mm
minimum
2
25 mm
minimum
2
25 mm
minimum
2