Dc-Kit4 With Dometic B3200; Adjustment - Waeco ECL-76 Instrucciones De Montaje

Distribuidor de corriente de carga
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 106

Adjustment

NOTE
I
Guide the on/off cable carefully past the fan.
➤ Connect both the wires on the universal connection cable (4441300124) to the two
wires on the on/off cable of the B2600.
7.10

DC-Kit4 with Dometic B3200

 Roof air conditioner: Dometic B3200
 Circuit diagram: fig. d, page 16
 Charging current distributor: ECL-102
 Inverter: SinePower MSP2012 (item no. MSP2000-012)
➤ Install inverter remote control MCR-9 (membrane button) in an easily-accessible place
(jumper closed, refer to remote control installation manual) and connect its cable to the
inverter.
➤ Unravel the 2-wire universal connection cable (on/off cable, item no. 4441300124)
so that you have two individual wires.
➤ Use the blue wire of the universal connection cable (item no. 4441300124) to join the
I5 connection of the ECL-102 to the MCR-9 remote control (use wire sleeves).
➤ Use the brown wire of the universal connection cable to join the D+ input to the
l2 connection on the ECL-102 (use wire sleeves).
8
Adjustment
NOTICE!
A
The following work must be carried out with caution and only by persons with the
necessary skills and knowledge. This is because incorrect adjustment of the cut-
in and cut-off voltages can cause the air conditioner to malfunction and/or cause
the vehicle's electrical system to fail.
NOTE
I
The voltage scale shown on the charging current distributor is a guide. If differ-
ent values are set, these must be checked using a suitable voltage measure-
ment device. An externally adjustable laboratory power supply can be
connected to terminals GND and D+ for this purpose.
➤ Insert the screwdriver into the axis of the potentiometer (fig. e, page 17). Turning the
axis clockwise increases the voltage threshold value, turning it anti-clockwise reduces
the voltage threshold value.
NOTE
I
Due to information presently available, we do not recommend a cut-off voltage
less than 11.5 V.
74
ECL-76, ECL-102
EN

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ecl-102

Tabla de contenido