Repairs - Wilo FK 17.1 Instrucciones De Instalación Y Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1119
-
Fig. 14: Sealing chamber: Oil change
9.6.9
General overhaul
9.7

Repairs

Installation and operating instructions Wilo Motor FK 17.1, FK 202, FK 34, FK 42 + EMU FA, Rexa SUPRA, Rexa SOLID
Maintenance and repair
Motors FK 202, FK 34, FK 42
+
Fill the oil in the sealing chamber
-
Drain the oil in the sealing chamber
Protective equipment has been put on!
Pump has been dismantled and cleaned (decontaminated if required).
1. Place the pump upright on a firm surface.WARNING! Risk of hands being crushed.
Ensure that the pump cannot fall over or slip away!
2. Place a suitable tank to collect the operating fluid.
+
3. Unscrew the screw plug (+) slowly, but do not unscrew it completely. WARN-
ING! Overpressure in the motor! Stop turning the screw plug further if hissing
or whistling is audible! Wait until the pressure has completely dissipated.
4. After the pressure has dissipated, fully unscrew the screw plug (+).
5. Unscrew screw plug (-) and drain the operating fluid. If a shut-off ball cock is in-
stalled on the outlet opening, open the shut-off ball cock.
6. Check the operating fluid: Notify customer service if the operating fluid contains
swarf!
7. If a shut-off ball cock is installed on the outlet opening, close the shut-off ball
cock.
8. Clean the screw plug (-), replace the seal ring and screw it back in. Max. tightening
torque: 8 Nm (5.9 ft·lb)!
9. Pour the new operating fluid in through the hole of the screw plug (+).
⇒ Comply with the specifications for operating fluid type and quantity!
10.Clean the screw plug (+), replace the seal ring and screw it back in. Max. tightening
torque: 8 Nm (5.9 ft·lb)!
During the general overhaul, the motor bearings, shaft sealings, O-rings and power
supply cables are checked for wear and damage. Damaged components are replaced
with original parts. This will ensure correct operation.
The general overhaul is performed by the manufacturer or an authorised service centre.
WARNING
Sharp edges on the impeller and suction port!
Sharp edges can form on the impeller and suction port. There is danger of limbs be-
ing severed! Protective gloves must be worn to protect from cuts.
WARNING
Hand, foot or eye injuries due to the absence of protective equipment!
Danger of (serious) injuries during work. Wear the following protective equipment:
• Safety gloves for protection against cuts
• Safety shoes
• Closed safety goggles
The following preconditions must be met prior to starting repair work:
▪ Pump cooled down to the ambient temperature.
▪ Pump is switched voltage-free and secured against being activated inadvertently.
▪ Pump cleaned thoroughly and disinfected (if required).
For repair work the following generally applies:
▪ Wipe up spillage quantities of fluid and operating fluid immediately!
▪ Always replace O-rings, gaskets and screw locking devices!
▪ Observe the tightening torques in the appendix!
▪ Never use force when carrying out this work!
en
187

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fk 202Fk 34Fk 42Emu fa

Tabla de contenido