  • ESPAÑOL, página 89
No. on Fig.1
1
2
3
4
5
6
7
8
9
10
11
12
13
8
Part
Remote switches/
programmable
buttons
Up/down
control wheel
Up/down
angulation lock
Suction valve
Insufflation/
rinsing valve
Right/left
control wheel
Right/left
angulation lock
Biopsy valve
Working channel
port
Insertion tube
Bending section
Distal tip
Insufflation/
rinsing nozzle
Function
The user activates functions on the displaying unit�
The functions of the remote switches/programmable
buttons are pre-configured from factory and can be
re-configured according to the user's preference�
Each button can be programmed to be sensitive
on both short and long press� See displaying unit
IFU for further details�
The Up/Down control wheel manipulates the
bending section of the endoscope� When this
wheel is turned in the "U" direction, the bending
section moves UP; when the wheel is turned in the
"D" direction, the bending section moves DOWN�
Turning this lock in the "F" direction frees angulation�
Turning the lock into the opposite direction locks
the bending section at any desired position along
the up/down axis�
The removable suction valve controls suction�
When pressed fully down, suction is activated to
remove any fluids, debris or gas from the patient�
The insufflation/rinsing valve controls insufflation
and lens rinsing� Placing a finger on the opening of
the valve activates insufflation� When pressed fully
down, lens rinsing is activated�
The Right/Left control wheel manipulates the
bending section of the endoscope� When this
wheel is turned in the "R" direction, the bending
section moves RIGHT; when the wheel is turned in
the "L" direction, the bending section moves LEFT�
Turning this lock in the "F" direction frees
angulation� Turning the lock into the opposite
direction locks the bending section at any desired
position along the right/left axis�
The biopsy valve seals the working channel�
The working channel functions as:
Suction channel�
Channel for the insertion or connection of
endotherapy accessories�
Fluid feed channel (from a syringe via
the biopsy valve)�
The flexible insertion tube is inserted into
the patient's upper GI tract�
The bending section is the maneuverable part
of the endoscope, that can be controlled by
the control wheels and angulation locks�
The distal tip holds the camera, the light
source (two LEDs), the working channel outlet,
the insufflation/rinsing nozzle, and the auxiliary
water jet outlet�
Nozzle for lens rinsing and insufflation�