Communication protocol
CHANGED (page 87): Process Data Objects
The following table shows the default Rx PDO mapping:
Rx PDO
Mapping object
1
1600
2
1601
3
1602
4
1603
6
1605
1)
21
1614
1)
Default mapping with ACS880 and ACS580:
2101 ABB Drives control word
2102 ABB Drives REF1
2103 ABB Drives REF2
The following table shows the default Tx PDO mapping:
Tx PDO
Mapping object
1
1A00
2
1A01
3
1A02
4
1A03
6
1A05
1)
21
1A14
1)
Default mapping with ACS880 and ACS580:
2104 ABB Drives status word
2105 ABB Drives ACT1
2106 ABB Drives ACT2
Object index
Object name
6040
Controlword
-
6040
Controlword
607A
Target position
6040
Controlword
60FF
Target velocity
6040
Controlword
6071
Target torque
6040
Controlword
6042
vl target velocity
2001
Transparent CW
2002
Transparent REF1
2003
Transparent REF2
Object index
Object name
6041
Statusword
-
6041
Statusword
6064
Position actual value
6041
Statusword
6064
Position actual value
6041
Statusword
6064
Position actual value
6077
Torque actual value
6041
Statusword
6044
vl velocity actual value
2004
Transparent SW
2005
Transparent ACT1
2006
Transparent ACT2
Update notice