This manual contains exclusive information protected by copyright
laws and we reserve its copyright. Without written approval of ma-
nufacturer no parts of this manual shall be photocopied, Xeroxed or
translated into other languages.
The contents contained in this manual are subject to amendments
without notification.
Manufacturer's Responsibility
Only under the following circumstances the manufacturer will be
responsible for the safety, reliability and performance of the instru-
ment:
•
All the installation, expansion, readjustment, renovation
or repairs are only meant to be conducted by personnel
certified by the manufacturer.
•
The storage condition, operation condition and electrical
status of the instrument conform to the product specifi-
cation.
•
The instrument is used in accordance with the user's ma-
nual.
About this manual
This manual contains the instructions necessary to operate the pro-
duct safely and in accordance with its function and intended use.
Observance of this manual is a prerequisite for proper product per-
formance and correct operation and ensures patient and operator
safety.
This manual is based on the maximum configuration and therefore
some contents may not apply to your product. If you have any que-
stions, please contact us.
This manual is an integral part of the product. It should always be
kept close to the equipment so that it can be obtained conveniently
when needed.
The manual is geared for clinical professionals who are expected
to have a working knowledge of medical procedures, practice and
terminology as required for monitoring patients.
All illustrations in this manual serve as examples only. They may
not necessarily reflect the setup or data displayed on your product.
Conventions:
•
Bold Italic text is used in this manual to quote the refe-
renced chapter or sections.
•
[ ] are used to enclose screen texts.
•
> is used to indicate operational procedures.
Signs in this manual:
Warning: Indicates a potential hazard or unsafe practice
that, if not avoided, will result in death or serious injury.
Caution: Indicates a potential hazard or unsafe practice
that, if not avoided, could result in minor personal injury or
product/property damage.
Note: Provides application tips or other useful information
to ensure that you get the most from your product.
Welcome to the Riester RVS-100
Thank you for choosing the Riester RVS-100 for accurate monitoring
of vital signs. The Riester RVS-100 is designed to be simple and
efficient to use and the RVS-100 features:
automatic patient monitoring modes
averaging of multiple BP readings
user-programmable monitoring intervals
audible and visual patient alarms
connection to EMR system
Riester RVS-100 Description and Operation
The Riester RVS-100 vital signs monitor can perform automatic
blood pressure, pulse oximetry and body temperature measure-
ments for clinical professionals. For measuring blood pressure, a
blood pressure cuff is placed around the patient's non-dominant
upper arm. The cuff is inflated automatically and blood pressure
is measured by the oscillometric method—which senses pressure
waves in the artery when occluded by pressure in the cuff. Measure-
ment of the frequency of the pressure waves enables heart rate
to also be measured. The pulse oximetry function non-invasively
measures the patient's percent oxygen saturation of arterial he-
moglobin using principles of plethysmography via a SpO2 sensor
placed on the patient's finger. Temperature can be measured using
an oral/axillary/rectal temperature probe containing a thermistor
44
that generates a voltage based on changes in temperature, and
these voltages are recorded by the temperature circuitry. The RVS-
100 is a portable device, approximately 350 x 245 x 115 mm in size
and weighs approximately 3006 g without battery. A color touch
screen allows the user to stop/start a BP measurement, save a set
of measurements to memory, control patient alarm functions, print
measurements, and return to the home screen. The touch screen
can also be used to select many different device options. The back-
lit LCD display shows the user device status and measurement
information. A set of multi-color LED's on the corner of the front
enclosure alert users to visual alarms. The device uses a micro-
processor with software, which is not accessible to the user. The
unit is powered by a single rechargeable lithium-ion battery at the
bottom of the device. Four USB-A port connections can be used to
connect optional barcode scanner or Wi-Fi dongle. An optional in-
ternal thermal printer is available. There is also RJ45 Ethernet port
for network connectivity and an RJ11 jack for nurse call connectivity.
Note: For purposes of this manual, the Riester RVS-100 may be re-
ferred to as "the Riester RVS-100", "the RVS-100," "the device" or
"the monitor".