User Instructions  MSA Remote Connect/Disconnect System
9.0
PRODUCT LABELS/ETIQUETAS DEL PRODUCTO/ÉTIQUETTES DU PRODUIT
INSTRUCTIONS FOR USE
TO INSERT AND REMOVE TOOLS:
1.
Refer to user Manual (P/N 622333) for proper use of tools.
2.
Connect tool adapter (P/N 506640 to end of pole. Secure with thumb
screw provided with pole.
3.
Insert appropriate tool by depressing spring-loaded retainer pins and
inserting tool shank into receptacle on pole. tip. Verity that both
retainer pins engage retainer pin holes.
4.
Remove tool by depressing both retainer pins and sliding tool out of
pole receptacle.
TO EXTEND POLE:
1)
Hold outer section and pull inner pole to desired length. Align etched
guide marks if present.
2)
Black buttons lock pole sections in extended position. Verify that the
pole sections are engaged and locked in place.
TO RETRACT POLE:
1.
Hold outer section, depress black button. Slowly slide inner section
into outer section. Twist to move latch button past hole.
2.
Collapse pole to shortest length for shortage.
TO INSPECT, MAINTAIN, AND STORE:
1.
Insepct before each use. Be sure extension member locks.
2.
Clean according to User Manual.
3.
Store pole retracted where it cannot fall, roll, be crushed, or bent.
© 2012 MSA
RCD®
TELESCOPING POLE
P/N 506639 & 506642
Fiberglass handle and extension.
Maximum extendable length 12 ft. (3.8 m)
Weight 3.0 lbs. (1.4 kg).
WARNING
READ AND HEED ALL INSTRUCTIONS IN USER
MANUAL (P/N 622333) PROVIDED SEPARATELY WITH
THIS PRODUCT. FAILURE TO DO SO MAY RESULT IN
SERIOUS INJURY OR DEATH. ALL USERS MUST
RECEIVE HANDS-ON TRAINING BY COMPETENT A
PERSON BEFORE USE.
CONTROL POLE AT ALL
TIMES.
POLE SLIPPERY WHEN WET. KEEP IT CLEAN
AND DRY.
WEAR HARD HAT AND SAFETY GLASSES
WHEN USING THIS EQUIPMENT.
USE ONLY WITH
THE FOLLOWING COMPONENTS OF THE MSA
REMOTE CONNECT/DISCONNECT SYSTEM:
Knife tool
Combination tool
-
10129597
Remote anchorage
Strap tool
-
506509
connector strap
WARNING
AVOID POWER LINES!
MAINTAIN A MINIMUM
CLEARANCE DISTANCE OF 10
FEET (3 m) FROM ELECTRICAL
SOURCES.
MAKE SURE OF SECURE FOOTING!
USE ONLY IN AREAS FREE OF TRIP
HAZARDS AND OBSTACLES. KEEP
WORKING AREA CLEAR.
DONT BE A HAZARD TO OTHERS!
BE AWARE OF WORKERS IN AREA
OF MOVEMENT. CLEAR
PERSONNEL FROM BELOW IN CASE
OF ACCIDENTAL RELEASE.
NEVER LEAN OUT WITHOUT
PROTECTION!
ALWAYS USE PROPER FALL ARREST /
-
506591
RESTRAINT SYSTEMS WHERE FALL
-
505314
HAZARDS EXIST.
P/N R622333