11.12 REPlACING ThE fUSES Of ThE POWER bOARD
1) To access the power board, follow steps 3 to 9 in section 11.7.
2) Locate the power board and undo the cartridge fuse holder. In the case of machines with three-phase power supply,
open the control box and take out also the main fuse holder of the power supply circuit.
3) Remove the fuses and use a tester to test their condition.
4) Replace damaged fuses with ones of the same characteristics.
5) Put the cartridges back in the fuse holders and fasten them with the screwdriver.
6) Close the machine following steps 13 to 19 in section 11.7.
Rev. 01 - 03/2018 - Cod. 1500024 - Instruction manual for vacuum chamber packaging machines for vacuum cooking mod.