Descargar Imprimir esta página

Samsung NSY6 855 Serie Manual Del Usuario página 57

Estufa deslizante de combustible dual

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting
If you encounter a problem with the range, check the tables starting below, and then try the
suggested actions.
Checkpoints
Gas safety
Problem
Possible cause
You smell gas.
The surface burner knob is
not in the Off position and
the burner is not lit.
There is a gas leak.
Action
Turn the burner knob to Off.
Clear the room, building, or area of
all occupants.
Immediately call your gas supplier
from a neighbor's phone. Do not
call from your phone. It is electrical
and could cause a spark that could
ignite the gas. Follow the gas
supplier's instructions.
If you cannot reach your gas
supplier, call the fire department.
Surface burner
Problem
Cause
All burners do not
The power cord is not
light.
plugged into the electrical
outlet.
A fuse in your home may be
blown or the circuit breaker
may have tripped.
The gas supply is not
properly connected or turned
on.
Surface burners do
The control knob is not set
not light.
properly.
The burner caps are not in
place.
The burner base is
misaligned.
Surface burner clicks
The control knob has been
during operation.
left in the Lite position.
The burners do not
Surface burner components
burn evenly.
and caps are not assembled
correctly and level.
The surface burners are
dirty.
Very large or yellow
The wrong burner orifice is
surface burner
installed.
flames.
Action
Make sure the electrical plug
is plugged into a live, properly
grounded outlet.
Replace the fuse or reset the
circuit breaker.
See the Installation Instructions
that came with your range.
Push in the control knob and turn
it to the Lite position.
Clean the electrodes.
Put the burner cap on the burner
head.
Align the burner base.
After the burner lights, turn the
control knob to a desired setting.
If the burner still clicks, contact a
service technician.
See page 51.
Clean the surface burner
components. (See page 50.)
Check the burner orifice size.
Contact your installer if you have
the wrong orifice (LP gas instead
of natural gas or natural gas
instead of LP gas).
English 57

Publicidad

loading