Siemens SINAMICS G130 Manual De Listas página 1020

Ocultar thumbs Ver también para SINAMICS G130:
Tabla de contenido

Publicidad

p2149.1
1
M_act
r0080
0
[5730.1] <3>
M_thresh 3 upper
[6714.8] <2>
0.00...20 000 000.00 Nm
p2189[D] (10 000 000.00)
M_thresh 3 lower
0.00...20 000 000.00 Nm
p2190[D] (0.00)
M_thresh 2 upper
0.00...20 000 000.00 Nm
p2187[D] (10 000 000.00)
M_thresh 2 lower
0.00...20 000 000.00 Nm
p2188[D] (0.00)
M_thresh 1 upper
0.00...20 000 000.00 Nm
p2185[D] (10 000 000.00)
M_thresh 1 lower
0.00...20 000 000.00 Nm
p2186[D] (0.00)
n_act smooth signal
0
r2169
[8010.2]
1
p2149.1
p3231[D] (150.00)
<2>
n_act load monitor
p3230[C]
(0)
+
<2>
Load monitor Encoder falling off
p3232[C]
(1)
<2>
<1> The response to these faults can be defined.
<2> Only for VECTOR.
<3> Only for SERVO.
1
2
DO: SERVO, VECTOR
Signals and monitoring functions - Load monitoring (r0108.17 = 1)
M [Nm]
Tolerance
bandwidth
n_threshold 1
n_threshold 2
0.00...210 000.00 RPM
0.00...210 000.00 RPM
p2182[D](150.00)
p2183[D](900.00)
1
0
1
3
4
A07926 "Envelop characteristic, parameter not value"
p2193[D] (1)
0.00...65.00 s
<2>
p2192[D] (10.00)
0
0
1
2
3
n [RPM]
n_threshold 3
0.00...210 000.00 RPM
p2184[D](1500.00)
5
6
fp_8013_54_eng.vsd
04.11.09 V04.03.01
p0115[6] (4000.00 μs)
Load monitoring response
p2181[D](0)
A07920 ... A07922
r2198.11
0
T
[2536.3]
Evaluation
F07923 ... F07925
r2198.12
[2536.3]
(0)
Load monitoring disabled
(1)
A07920 "Torque too low"
(2)
A07921 "Torque too high"
A07922 "Torque outside tolerance"
(3)
(4)
F07923 "Torque too low"
<1>
(5)
F07924 "Torque too high"
<1>
(6)
F07925 "Torque outside tolerance"
<1>
F07928 "Encoder falling off"
<2>
7
Function diagram
S120/S150/G130/G150
8
- 8013 -

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sinamics g150

Tabla de contenido