Siemens SINAMICS G130 Manual De Listas página 1274

Ocultar thumbs Ver también para SINAMICS G130:
Tabla de contenido

Publicidad

Bit 9 = 1 --> Ready to exchange process data
Status word CANopen Bit 8 = 0: from speed signals 2 [8011.8] (r2197.7)
Status word CANopen Bit 8 = 1: From status word monitoring 3 [8010.8] (r2199.0)
From status word speed controller [2522]
From status word monitoring 3 [8010.8] (r2199.0)
<1> With setpoint channel: connect p2151 with r1119 [8010.5].
<2> Only if p8791 = 1 or 3.
1
2
DO: A_INFM2C, SERVO, VECTOR, VECTOR3P, VECTORGL, VECTORMV, VECTORSL
Communication Board CAN10 (CBC10) - Status word, CANopen
Bit No.
From sequence control [2610]
0
From sequence control [2610]
1
From sequence control [2610]
2
From fault buffer [8060]
3
From sequence control [2610]
4
From sequence control [2610]
5
From sequence control [2610]
6
From alarm buffer [8065]
7
p8785
(0)
8
9
10
11
12
13
p8786
(0)
14
p8787
(0)
15
3
4
Status word CANopen
1 = Rdy for switch on
1 = Ready (DC link loaded, pulses blocked)
1 = Operation enabled (drive follows n_set)
1 = Fault present
1 = No coasting active
1 = No Quick Stop active
1 = Switching on inhibited active
1 = Alarm present
Can be freely interconnected (BI: p8785)
1 = Control request
1 = Target reached <1>
1 = Torque limit reached
1 = Velocity equal to zero
Reserved
Can be freely interconnected (BI: p8786)
Can be freely interconnected (BI: p8787)
5
fp_9226_51_eng.vsd
24.02.14 V04.07.00
CAN bus sampling time
Status word CANopen
r8784
6
7
Function diagram
SINAMICS
8
- 9226 -

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sinamics g150

Tabla de contenido