SYSTEME D'ALLUMAGE
AC MAGNETO INSPECTION
1.
Inspect:
• Pickup coil resistance
Out of specification →
Replace.
Tester (+) lead → Red lead 1
Tester (–) lead → White lead 2
Pickup coil
resistance
248 ~ 372 Ω at
20 °C (68 °F)
NEUTRAL SWITCH INSPECTION
1.
Inspect:
• Neutral switch conduct
Tester (+) lead →
Sky blue lead 1
Tester (–) lead → Ground 2
Sb
Ground
1
2
NEUTRAL
IN GEAR
No continuity while in neutral →
Replace.
Continuity while in gear → Replace.
EC628000
CDI UNIT INSPECTION
Check all electrical components. If
no fault is found, replace the CDI
unit. Then check the electrical com-
ponents again.
7 - 17
IGNITION SYSTEM
CONTROLE DE L'ALTERNATEUR
AVEC ROTOR A AIMENTATION
PERMANENTE
1.
Contrôler:
• Résistance de la bobine d'excita-
tion
Hors spécifications → Remplacer.
Fil (+) du multimètre →
Tester
Fil (–) du multimètre → fil blanc 2
selector
position
Résistance de la
Ω × 100
CONTROLE DU CONTACTEUR DE
POINT MORT
1.
Contrôler:
• Continuité du contacteur de point
mort
Fil (+) du multimètre →
Fil (–) du multimètre → terre 2
Tester
selector
position
Ω × 1
POINT
MORT
EN
VITESSE
Pas de continuité au point mort → Rem-
placer.
Continuité en vitesse → Remplacer.
CONTROLE DU BOITIER C.D.I.
Vérifier tous les composants électriques.
Si aucun défaut n'est trouvé, remplacer
le boîtier CDI, puis vérifier à nouveau
les composants électriques.
–
+
ELEC
fil rouge 1
Position du
bobine
sélecteur du
d'excitation
multimètre
248 à 372 Ω à
Ω × 100
20 °C (68 °F)
fil bleu ciel 1
Position du
Sb
Terre
sélecteur
1
2
du multi-
mètre
Ω × 1