Table 1.D Minimum Recommended Branch Circuit Protective Devices
Voltage
Drive Rating
Rating
kW (HP)
120V AC –
0.2 (0.25)
1-Phase
0.37 (0.5)
0.75 (1.0)
240V AC –
0.2 (0.25)
1-Phase
0.37 (0.5)
0.75 (1.0)
1.5 (2.0)
240V AC –
0.2 (0.25)
3-Phase
0.37 (0.5)
0.75 (1.0)
1.5 (2.0)
2.2 (3.0)
3.7 (5.0)
480V AC –
0.37 (0.5)
3-Phase
0.75 (1.0)
1.5 (2.0)
2.2 (3.0)
3.7 (5.0)
(1)
Recommended Fuse Type: UL Class J, CC, T or Type BS88; 600V (550V) or
equivalent.
(1)
Fuse Rating
140M Motor
Amps
Protectors
Catalog No.
10
140M-C2E-C10
15
140M-C2E-C16
30
140M-D8E-C20
10
140M-C2E-B63
10
140M-C2E-B63
15
140M-C2E-C16
30
140M-D8E-C20
3
140M-C2E-B25
6
140M-C2E-B40
10
140M-C2E-C10
15
140M-C2E-C16
25
140M-C2E-C16
35
140M-F8E-C25
3
140M-C2E-B25
6
140M-C2E-B40
10
140M-C2E-B63
15
140M-C2E-C10
15
140M-C2E-C16
Installation/Wiring
Recommended
MCS Contactors
Catalog No.
100-C09
100-C12
100-C23
100-C09
100-C09
100-C12
100-C23
100-C09
100-C09
100-C09
100-C12
100-C16
100-C23
100-C09
100-C09
100-C09
100-C09
100-C16
1-7