Advanced Program Group
A084 [Start Boost]
Sets the boost voltage (% of P031
(1)
Drive may add additional voltage unless Option 5 is selected.
Options 1 "30.0"
2 "35.0"
3 "40.0"
4 "45.0"
5 "0.0 no IR Comp"
6 "0.0"
7 "2.5"
[Default for 3.7kW
(5HP) Drives]
8 "5.0" (Default)
9 "7.5"
10 "10.0"
11 "12.5"
12 "15.0"
13 "17.5"
14 "20.0"
100
1/2 [Motor NP Volts]
50
Settings
5-14
0
% [Motor NP Hertz]
A088 [Maximum Voltage]
Sets the highest voltage the drive will output.
Values
Default
Min/Max:
Display:
[Motor NP
4
3
2
1
50
100
Drive Rated Volts
20/Drive Rated Volts
1 VAC
Programming and Parameters
(continued)
Volts]) and redefines the Volts per Hz curve.
Variable Torque
Constant Torque
Related Parameter(s):
(1)
3-19
P031