Gram IF 4000 Manual De Uso página 351

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3-30
Programming and Parameters
Advanced Program Group
A105 [Comm Loss Action]
Selects the drive's response to a loss of the communication connection or excessive communication
errors.
Options 0 "Fault" (Default)
1 "Coast Stop"
2 "Stop"
3 "Continu Last"
A106 [Comm Loss Time]
Sets the time that the drive will remain in communication loss before implementing the option selected
in
A105
[Comm Loss Action].
Values
Default
Min/Max:
Display:
A107 [Comm Format]
Selects the protocol (RTU only), data bits (8 data bits only), parity (None, Even, Odd), and stop bits (1
stop bit only) used by the RS485 port on the drive.
Refer to
Appendix C
for details on using the drive communication features.
Important: Power to drive must be cycled before any changes will affect drive operation.
Options 0 "RTU 8-N-1" (Default)
1 "RTU 8-E-1"
2 "RTU 8-O-1"
A108 [Language]
Selects the language displayed by the remote communications option.
Options 1 "English" (Default)
2 "Français"
3 "Español"
4 "Italiano"
5 "Deutsch"
6 "Reserved"
7 "Português"
8 "Reserved"
9 "Reserved"
10 "Nederlands"
(continued)
Related Parameter(s): d015, P037,
Drive will fault on an F81 Comm Loss and coast to stop.
Stops drive via coast to stop.
Stops drive via
P037
[Stop Mode] setting.
Drive continues operating at communication commanded
speed saved in RAM.
5.0 Secs
0.1/60.0 Secs
0.1 Secs
Related Parameter(s): d015,
Related Parameter(s):
A106
A105
d015

Publicidad

Capítulos

Tabla de contenido
loading

Productos relacionados para Gram IF 4000

Tabla de contenido