Advanced Program Group
A135 [PID Integ Time]
Sets the value for the PID integral component when the PID mode is enabled by A132 [PID Reference
Select].
Values
Default
Min/Max:
Display:
A136 [PID Diff Rate]
Sets the value for the PID differential component when the PID mode is enabled by A132 [PID
Reference Select].
Values
Default
Min/Max:
Display:
A137 [PID Setpoint]
Provides an internal fixed value for process setpoint when the PID mode is enabled by A132 [PID
Reference Select].
Values
Default
Min/Max:
Display:
A138 [PID Deadband]
Sets the lower limit of the PID output.
Values
Default
Min/Max:
Display:
A139 [PID Preload]
Sets the value used to preload the integral component on start or enable.
Values
Default
Min/Max:
Display:
Programming and Parameters
(continued)
0.1 Secs
0.0/999.9 Secs
0.1 Secs
0.01 (1/Secs)
0.00/99.99 (1/Secs)
0.01 (1/Secs)
0.0%
0.0/100.0%
0.1%
0.0%
0.0/10.0%
0.1%
0.0 Hz
0.0/400.0 Hz
0.1 Hz
3-37